This paper presents a novel transformer magnetic biasing control method for high-power high-performance AC power supplies. Serious consequences due to magnetic biasing and several methods to overcome magnetic biasing are first discussed. The causes of the transformer magnetic biasing are then analyzed in detail. The proposed method is based on a high-pass filter inserted in the forward path and the feedforward control. Without testing magnetic biasing of transformer, this method can eliminate magnetic biasing of transformer completely in real-time waveform feedback control systems though the zero error of the Hall effect sensors varies with time and temperature. The met hod has already been employed in a 90KVA AC power supply. It is shown that It offers improved perforrnauce over existing ones, In this method, no sensors are used such that the zero error of the Hall effect sensors has not any influence on the system. It is simple to design and implement. Furthermore, the method is suitable for various power appllcations.
机译:本文提出了一种用于大功率高性能交流电源的新型变压器磁偏置控制方法。首先讨论了由于磁偏置产生的严重后果以及克服磁偏置的几种方法。然后详细分析变压器磁偏的原因。所提出的方法基于在前向路径中插入的高通滤波器和前馈控制。尽管霍尔效应传感器的零误差会随时间和温度变化,但无需测试变压器的磁偏置,该方法就可以在实时波形反馈控制系统中完全消除变压器的磁偏置。该方法已在90KVA交流电源中使用。结果表明,与现有的传感器相比,它提供了更好的性能。在这种方法中,由于没有使用传感器,因此霍尔效应传感器的零误差对系统没有任何影响。设计和实施都很简单。此外,该方法适用于各种功率应用。