首页> 外文期刊>Building Services Engineering Research & Technology >A new design guideline for the heating and cooling curve in AHU units of HVAC systems
【24h】

A new design guideline for the heating and cooling curve in AHU units of HVAC systems

机译:HVAC系统AHU单元中加热和冷却曲线的新设计准则

获取原文
获取原文并翻译 | 示例

摘要

New Dutch office buildings are built under strict energy efficient legislation and are well equipped with insulation, condensing boilers, heat recovery systems, and so on. Despite this, many buildings do not have good energy efficiency and also do not meet comfort requirements. This has led to a large number of complaints. The problem seems to be that 'common' energy control strategies (heating/ cooling curves) are often used, most of the curves were based on buildings with low levels of building shell heating resistance, no additional insulation and single glazing. When these control strategies are used in modern office buildings, too much energy is used due to a mismatch between heating and cooling" demands. Energy savings of up to 35% can be realized without significant financial investments by devoting extra attention to the settings of the heating/ cooling curve in the central air handling units (AHUs) of HVAC systems without loss of comfort. In most cases the number of complaints will also be reduced. The design method can be used in both new and existing buildings. The first part of this paper presents a brief description of the method used to realize this energy saving. The brief description is followed with a practical example of this method. The intention is that the approach will generate a building-specific heating/cooling curve based on an energetic optimum between the demand for heating and cooling in the zones. The input data used to generate the function cover the characteristics of the building, the organization, and the HVAC equipment.
机译:荷兰的新办公大楼是根据严格的节能法规建造的,并配备了保温,冷凝锅炉,热回收系统等。尽管如此,许多建筑物仍没有良好的能源效率,也无法满足舒适性要求。这导致了大量投诉。问题似乎在于,经常使用“通用”能量控制策略(加热/冷却曲线),大多数曲线基于建筑物外壳的耐热性低,没有额外的隔热和单层玻璃的建筑物。当这些控制策略用于现代办公大楼时,由于供暖和制冷需求不匹配而消耗了过多的能源。通过特别注意照明设备的设置,无需大量的财务投资就可以节省多达35%的能源。暖通空调系统中央空调(AHU)的加热/冷却曲线,而不会降低舒适度,在大多数情况下,抱怨的数量也会减少,该设计方法可以在新建筑物和现有建筑物中使用。本文简要介绍了实现该节能的方法,并以该方法的一个实际示例进行了简要说明,目的是该方法将基于能量最优生成建筑物特定的供热/制冷曲线。区域的供暖和制冷需求之间的关系用于生成功能的输入数据涵盖了建筑物,组织和HVAC设备的特征ment

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号