首页> 外文期刊>Biomedical signal processing and control >Digital Breast Tomosynthesis imaging using compressed sensing based reconstruction for 10 radiation doses real data
【24h】

Digital Breast Tomosynthesis imaging using compressed sensing based reconstruction for 10 radiation doses real data

机译:使用基于压缩感测的重建技术对10辐射剂量进行数字化乳房断层合成成像真实数据

获取原文
获取原文并翻译 | 示例

摘要

Purpose: Digital Breast Tomosynthesis (DBT) has recently proved promising in producing three-dimensional (3D) images of a breast. Algebraic reconstruction technique (ART), which is one of the most frequently used iterative image reconstruction techniques, has been proposed to provide satisfactory images of the breast in detecting masses and micro-calcifications. However, the greatest limitation of DBT imaging is the level of radiation dose due to the very sensitive nature of the breast. Recently, the effect of total variation (TV) minimization to enhance the image quality and to reduce the noise has been investigated in DBT imaging. Studies dealing with 3D TV minimization with ART have attracted increasing attention in the field of image reconstruction. This work investigates if iterative reconstruction techniques applied without and with TV (ART and ART + TV3D) can help reduce the level of dose in DBT imaging.Methods: Projections of a realistic breast phantom (CD Pasmam 1054) were acquired with a Siemens MAMMOMAT DBT scanner at 10 different doses. The effect of dose and the methods in the reconstruction quality was assessed both quantitatively and qualitatively.Results: ART+ TV3D showed superior results in terms of visual assessment, contrast-to-noise ratio (CNR) and full width at half maximum (FWHM) values, and one-dimensional (1D) profiles compared with ART. CNR values were evaluated for two different regions of interest (ROls). For instance, CNR values of ROI-1 of ART and of ART + TV3D were 46.380 and 47.675 at 63 mAs, 48.945 and 50.632 at 90 mAs, and 51.248 and 52.867 at 199 mAs, respectively. Additionally, FWHM values for ART and ART + TV3D were 2.373 and 1.758 at 63 mAs, 1.930 and 1.467 at 90 mAs, and 1.591 and 1.223 at 199 mAs, respectively.Conclusions: The results suggested that a compressed sensing based iterative reconstruction method (ART +TV3D) could help decrease the radiation dose level that is one of the most critical limitations of DBT imaging. (C) 2018 Published by Elsevier Ltd.
机译:目的:最近证明,数字乳房断层合成(DBT)在产生乳房的三维(3D)图像方面很有前途。代数重建技术(ART)是最常用的迭代图像重建技术之一,已提出在检测肿块和微钙化方面提供令人满意的乳房图像。但是,由于乳房非常敏感,DBT成像的最大局限性在于辐射剂量水平。近来,已经在DBT成像中研究了使总变化(TV)最小化以增强图像质量并降低噪声的效果。关于使用ART进行3D电视最小化的研究在图像重建领域引起了越来越多的关注。这项工作研究了是否在电视上使用和不使用电视(ART和ART + TV3D)的迭代重建技术是否可以帮助降低DBT成像的剂量水平。方法:使用西门子MAMMOMAT DBT获得了逼真的乳房幻影(CD Pasmam 1054)的投影10种不同剂量的扫描仪。定量和定性评估了剂量和方法对重建质量的影响。结果:ART + TV3D在视觉评估,对比度-噪声比(CNR)和半高全宽(FWHM)值方面显示出优异的结果以及与ART相比的一维(1D)配置文件。针对两个不同的关注区域(ROls)评估了CNR值。例如,ART和ART + TV3D的ROI-1的CNR值在63 mAs时分别为46.380和47.675,在90 mAs时分别为48.945和50.632,在199 mAs时分别为51.248和52.867。此外,ART和ART + TV3D的FWHM值在63 mAs时分别为2.373和1.758,在90 mAs时分别为1.930和1.467,在199 mAs时分别为1.591和1.223。结论:结果表明,采用基于压缩感测的迭代重建方法(ART + TV3D)可以帮助降低辐射剂量水平,这是DBT成像的最关键限制之一。 (C)2018由Elsevier Ltd.发布

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号