首页> 外文期刊>IEEE Transactions on Biomedical Engineering >Ferromagnetic high-permeability alloy alone can provide sufficient low-frequency and eddy-current shieldings for biomagnetic measurements
【24h】

Ferromagnetic high-permeability alloy alone can provide sufficient low-frequency and eddy-current shieldings for biomagnetic measurements

机译:单独的铁磁高磁导率合金可以为生物磁测量提供足够的低频和涡流屏蔽

获取原文
获取原文并翻译 | 示例

摘要

A low cost, two-shell ferromagnetic shielded room large enough for a person to enter and prepare experiments was constructed for biomagnetic measurements. No aluminium or copper shell was used for eddy-current shielding. A high-permeability nickel-iron-molybdenum alloy (1.57 mm thick) was used for both ferromagnetic and eddy-current shieldings. The shielding factor was 60 dB at DC and 40 dB between 0.1 Hz and about 3 Hz. The eddy-current shielding due to the alloy alone provided a shielding factor of 55 dB at 30 Hz and 66 dB at 60 Hz. The shielding factor was sufficiently high in all the frequency range for biomagnetic measurements with a first-order superconducting gradiometer.
机译:建造了一个低成本的两层铁磁屏蔽室,其空间足以供人进入并准备实验以进行生物磁测量。没有铝或铜壳用于涡流屏蔽。高磁导率的镍-铁-钼合金(1.57毫米厚)既用于铁磁屏蔽,也用于涡流屏蔽。直流的屏蔽系数为60 dB,0.1 Hz至约3 Hz之间的屏蔽系数为40 dB。仅由合金引起的涡流屏蔽在30 Hz时提供55 dB的屏蔽系数,在60 Hz时提供66 dB的屏蔽系数。对于一阶超导梯度仪进行生物磁测量,屏蔽系数在所有频率范围内都足够高。