首页> 外文期刊>IEEE Transactions on Biomedical Engineering >Robust Longitudinal Ankle Edema Assessment Using Wearable Bioimpedance Spectroscopy
【24h】

Robust Longitudinal Ankle Edema Assessment Using Wearable Bioimpedance Spectroscopy

机译:使用可穿戴生物阻抗光谱法的鲁棒纵向脚踝水肿评估

获取原文
获取原文并翻译 | 示例

摘要

Objective: We present a robust methodology for tracking ankle edema longitudinally based on bioimpedance spectroscopy (BIS). Methods: We designed a miniaturized BIS measurement system and employed a novel calibration method that enables accurate, high-resolution measurements with substantially lower power consumption than conventional approaches. Using this state-of-the-art wearable BIS measurement system, we developed a differential measurement technique for robust assessment of ankle edema. This technique addresses many of the major challenges in longitudinal BIS-based edema assessment, including day-to-day variability in electrode placement, positional/postural variability, and intersubject variability. Results: We first evaluated the hardware in bench-top testing, and determined the error of the bioimpedance measurements to be 0.4 omega for the real components and 0.54 omega for the imaginary components with a resolution of 0.2 omega. We then validated the hardware and differential measurement technique in: 1) an ex vivo, fresh-frozen, cadaveric limb model, and 2) a cohort of 11 human subjects for proof of concept (eight healthy controls and five subjects with recently acquired acute unilateral ankle injury). Conclusion: The hardware design, with novel calibration methodology, and differential measurement technique can potentially enable long-term quantification of ankle edema throughout the course of rehabilitation following acute ankle injuries. Significance: This could lead to better-informed decision making regarding readiness to return to activities and/or tailoring of rehabilitation activities to an individual's changing needs.
机译:目的:我们纵向基于生物阻抗光谱(BIS)纵向跟踪踝水肿的鲁棒方法。方法:我们设计了一种小型化的BIS测量系统,采用了一种新颖的校准方法,可实现比传统方法的功耗大得多,高分辨率测量。使用这种最先进的可穿戴BIS测量系统,我们开发了一种差分测量技术,用于踝海水米的强大评估。该技术解决了纵向基于BIS的水肿评估中的许多主要挑战,包括电极放置,位置/姿势变异性和运动器的日常变异性。结果:我们首先在台式测试中评估硬件,并确定生物阻抗测量的误差为0.4ω的真实组件和0.54 omega的虚部,具有0.2ω的分辨率。然后我们验证了以下硬件和差分测量技术:1)前体内,新鲜冻结,尸体肢体模型,以及2)概念证明的11人受试者(八个健康对照和最近获得的急性单侧的五个受试者)的群组脚踝受伤)。结论:具有新型校准方法和差分测量技术的硬件设计可以在急性踝关节伤害后的康复过程中能够长期定量脚踝水肿。意义:这可能导致更好地了解有关愿意恢复活动和/或裁缝对个人不断变化的需求的康复活动的决策。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号