Simplified approach to measuring semivolatile inorganic particulate matter using a denuded cellulose filter without backup filters

机译:使用不带备用过滤器的裸露纤维素过滤器测量半挥发性无机颗粒物的简化方法

获取原文
获取原文并翻译 | 示例

摘要

The use of uncoated denuded cellulose (CE) fibre filters without backup filters was explored as a simple means of accurately sampling semivolatile inorganic particulate matter. CE filters are particularly well suited for the purpose in question because they quantitatively absorb the gaseous constituents evolving from volatilised ammonium nitrate and chloride. A CE filter was placed behind a pair of recently developed mini parallel-plate denuders to form a very compact "Denuded-CE-filter Sampler" (DCES). The concentrations of the three major inorganic ions (SO42-, NO3-, and NH4+) determined with the DCES were compared with results obtained with a collocated ChembComb sampling cartridge featuring two honeycomb denuders, a Teflon (Tf) particle filter, and two backup filters. The 4 concentrations, measured with the two units to validate correspondence for non-volatile inorganic salts, were found to be in excellent agreement. The NO3- concentrations also agreed very well, even for sampling campaigns during which up to 95% of the particulate nitrate had evaporated from the Tf filter of the ChembComb. This agreement provides evidence that the DCES concept is reliable. The NH4+ concentrations, on the other hand, repeatedly differed significantly. The differences are attributed to the evaporation of NH3 from particulate matter other than NH4NO3, presumably organic ammonia compounds or bioaerosols. This evaporating NH3 is presumably not retained by the CE filter. As to the gases, the concentrations determined with the two types of denuders agreed quite well for HNO3. In case of SO2, the results obtained with the ChembComb were lower by about 10% than with the DCES. Large differences in both directions were observed for the (apparent) NH3 concentrations, which furthermore, were quite high. Sampling close to vegetation might have been the cause of the observed discrepancies. (c) 2006 Elsevier Ltd. All rights reserved.
机译:探究使用不带备用过滤器的未涂覆的裸露纤维素(CE)纤维过滤器,作为准确采样半挥发性无机颗粒物的简单方法。 CE过滤器特别适合用于上述目的,因为它们可以定量吸收挥发的硝酸铵和氯化物释放出的气态成分。将CE过滤器放置在一对最近开发的微型平行平板剥蚀器后面,以形成非常紧凑的“ Denuded-CE-filter Sampler”(DCES)。将使用DCES测定的三种主要无机离子(SO42-,NO3-和NH4 +)的浓度与并置的ChembComb采样柱获得的结果进行比较,该采样柱具有两个蜂窝状剥蚀器,一个Teflon(Tf)颗粒过滤器和两个备用过滤器。发现用这两个单位测量的4个浓度可以很好地证明非挥发性无机盐的相对应性。即使在采样过程中,高达95%的硝酸盐颗粒从ChembComb的Tf过滤器中蒸发了,NO3-的浓度也非常一致。该协议提供了DCES概念可靠的证据。另一方面,NH4 +浓度反复显着不同。差异归因于NH3从NH4NO3以外的颗粒物质(大概是有机氨化合物或生物气溶胶)中蒸发。蒸发的NH3可能不会被CE过滤器保留。关于气体,用两种类型的剥蚀仪测定的浓度对于HNO3相当吻合。对于SO2,使用ChembComb获得的结果要比使用DCES降低约10%。对于(表观)NH3浓度,在两个方向上都观察到很大的差异,此外,NH3的浓度也很高。在植被附近取样可能是观察到差异的原因。 (c)2006 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号