首页> 外文期刊>Aerosol and Air Quality Research >Characterization of Volatilization of Filter-Sampled PM2.5 Semi-Volatile Inorganic Ions Using a Backup Filter and Denuders
【24h】

Characterization of Volatilization of Filter-Sampled PM2.5 Semi-Volatile Inorganic Ions Using a Backup Filter and Denuders

机译:使用备用过滤器和剥蚀仪表征过滤器采样的PM2.5半挥发性无机离子的挥发特性

获取原文
           

摘要

The characteristics of the volatilization of semi-volatile inorganic ions sampled on a Teflon filter were investigated using a backup nylon filter and annular denuders. The volatilization ratio (VR) was defined as the fraction of the concentration at the backup filter and denuder to the sum of the concentrations collected at the Teflon filter, backup filter, and denuder. Particles whose aerodynamic diameters are less than or equal to 2.5 μm (PM2.5) were sampled for 24 h each season from summer 2011 to spring 2012 at a site, about 35 km southeast of downtown Seoul. Increase in VR with increasing temperature was evident, but the effects of relative humidity were not clear, because seasonal variation in the two variables was correlated, and the variation in relative humidity was smaller than that in temperature. While VRs generally decreased with the amounts sampled on the Teflon filter, details of the volatilization behaviors varied among ions according to concentrations at the Teflon filter and VR. The removal of gaseous species at the upstream denuders affected VRs of semi-volatile ions by shifting the equilibrium among NH4+, NO3–, and SO42–.
机译:使用备用尼龙过滤器和环形剥蚀器研究了在特氟隆过滤器上采样的半挥发性无机离子的挥发特性。挥发比(VR)定义为备用过滤器和裸露器处的浓度与在特氟隆过滤器,备用过滤器和裸露器中收集的浓度之和的分数。从2011年夏季到2012年春季,每个季节对空气动力学直径小于或等于2.5μm(PM2.5)的颗粒进行采样,采样时间为24小时,位于首尔市中心东南约35公里处。随着温度的升高,VR明显增加,但相对湿度的影响尚不明确,因为两个变量的季节变化相关,并且相对湿度的变化小于温度的变化。尽管VR通常随着在Teflon过滤器上采样的数量而减少,但根据Teflon过滤器和VR的浓度,离子之间的挥发行为细节有所不同。通过消除NH4 +,NO3–和SO42–之间的平衡,上游剥蚀器中气态物质的去除影响了半挥发性离子的VR。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号