Improving Accuracy of Asphalt Content Determination by Ignition Test

机译:通过点火试验提高沥青含量的测定精度

获取原文
获取原文并翻译 | 示例

摘要

Accurate determination of asphalt content and aggregate gradation is critical for controlling the quality of asphalt mixtures during construction. Most state specifications require quantitative evaluation of the asphalt content of mixes as a criterion for acceptance. The ignition oven test procedure specified in AASHTO T 308 is required or allowed by most state DOTs for determining the asphalt content and aggregate gradation of asphalt mixtures. The ignition oven test specified in AASHTO T 308 requires the determination of asphalt content correction factors for each asphalt mix and for each ignition oven used. However, in some instances when numerous asphalt mix designs and several ignition ovens are available, correction factors (CFs) are shared between ignition units, even when that practice is not allowed by the standard. There is a need to identify the consequences of sharing correction factors between units/mixes and also to identify testing parameters that affect the measured CFs. By identifying possible causes of variation, the test procedure could be adjusted to make the CFs more consistent between ignition ovens. Also, it should be possible to reduce the amount of difference in CFs between all types of equipment. A study was conducted to assess the variability of ignition oven CFs for different ignition oven unit brands and mixes to better understand the implications of sharing CFs. Twenty-three laboratories used various brands of ovens to test four mixes containing aggregates with varying CFs. The results indicated that CFs were significantly different for the different mixes even when same brand of unit was used. The within lab and between lab precision developed in this study suggests that different precision statements are necessary for aggregates with high breakdown potential and that the current precision included in AASHTO T 308 was likely developed for low weight loss aggregate making it unacceptable to use for aggregates with higher CFs. It was also found that the addition of lime caused no significant difference in the measured asphalt content when the CF was correctly measured. However, it was cautioned that a change in amount of lime during mixture production would affect the measured asphalt content. In addition, ways to minimize variability in asphalt CF were evaluated. It was determined that ignition tests conducted at lower temperature (427℃) proved to be effective in reducing the variability in measured asphalt content since the lower temperature reduced the asphalt correction factors for asphalt mixes.
机译:准确确定沥青含量和骨料等级对控制施工期间沥青混合物的质量至关重要。大多数州的规范要求对混合料中沥青含量进行定量评估,以此作为验收标准。大多数州DOT都要求或允许AASHTO T 308中规定的点火炉测试程序来确定沥青含量和沥青混合物的总级配。 AASHTO T 308中规定的点火炉测试要求确定每种沥青混合料和所用每种点火炉的沥青含量校正因子。但是,在某些情况下,即使有许多沥青混合料设计和多个点火炉可供使用,即使在标准不允许的情况下,点火装置之间也会共用校正因子(CF)。需要确定在单位/混合物之间共享校正因子的结果,并且还需要确定影响所测CF的测试参数。通过确定可能的变化原因,可以调整测试程序以使点火炉之间的CF更加一致。同样,应该有可能减少所有类型设备之间CF的差异。进行了一项研究,以评估不同品牌的点火炉单元和混合物的点火炉CF的可变性,以便更好地了解共享CF的含义。 23个实验室使用了各种品牌的烤箱来测试包含CF含量不同的骨料的四种混合物。结果表明,即使使用相同品牌的单位,对于不同的混合物,CF值也显着不同。在这项研究中开发的实验室内部和实验室之间的精度表明,对于具有高击穿潜力的集料,必须使用不同的精度声明,并且AASHTO T 308中包含的当前精度可能是针对低失重集料而开发的,因此对于具有较高的CF。还发现,当正确测量CF时,添加石灰不会引起沥青含量的明显变化。但是,需要注意的是,混合物生产过程中石灰含量的变化会影响所测沥青含量。另外,评估了使沥青CF的可变性最小化的方法。经确定,在较低温度(427℃)下进行的点火测试可有效减少所测沥青含量的变化,因为较低温度降低了沥青混合料的沥青修正系数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号