首页> 外文期刊>IEEE Transactions on Applied Superconductivity >Correlation of critical current density and phase conversion at different final cooling rate in Ag-sheathed PbBi2223 tapes
【24h】

Correlation of critical current density and phase conversion at different final cooling rate in Ag-sheathed PbBi2223 tapes

机译:Ag包覆的PbBi2223胶带在不同最终冷却速率下的临界电流密度和相变的相关性

获取原文
获取原文并翻译 | 示例

摘要

As shown by Parrell et al., a final reduced cooling rate can produce an improvement of the optimum critical current in field. In this paper we present results on the critical current density and magnetic field dependence of Ag-sheathed (Pb,Bi)-2223 multifilamentary tapes as a function of the final sintering time for different cooling. Correlation between 2223 phase conversion, as determined by XRD, and the critical current density is also examined. For samples slow cooled to 800/spl deg/C at 1/spl deg/C/h followed by furnace cooling to room temperature, the critical current density remained almost constant at 20 KAcm/sup -2/ with different final sintering times between 10 to 150 hours. In contrast samples slow-cooled to 730/spl deg/C at 1/spl deg/C/h showed a decreased J/sub c/ of 7 KAcm/sup -2/ for a short final sintering time of 10 hours, rising gradually to 22 KAcm/sup -2/ at 200 hours. Corresponding to this, the samples cooled to 800/spl deg/C show a phase composition of 90% apparent (Pb,Bi)-2223 for all times, as opposed to a gradual increase of the (Pb,Bi)-2223 phase from 65% to 90% with increasing sintering time for samples slow cooled to 730/spl deg/C. As the conditions are exactly the same prior to the cooling below 800/spl deg/C, the reduced conversion for the samples slow cooled to 730/spl deg/C must be the result of 2212 precipitation from the apparent (Pb,Bi)-2223 phase present at 800/spl deg/C.
机译:如Parrell等人所示,最终降低的冷却速度可以改善现场的最佳临界电流。在本文中,我们介绍了不同冷却条件下,Ag护套(Pb,Bi)-2223复丝带的临界电流密度和磁场依赖性与最终烧结时间的关系。还检查了由XRD确定的2223相变与临界电流密度之间的相关性。对于以1 / spl deg / C / h缓慢冷却至800 / spl deg / C,然后炉冷却至室温的样品,临界电流密度几乎保持恒定在20 KAcm / sup -2 /,最终烧结时间为10到150小时相比之下,在1 / spl deg / C / h下缓慢冷却至730 / spl deg / C的样品显示J / sub c /降低了7 KAcm / sup -2 /,最终烧结时间为10小时,逐渐降低200小时达到22 KAcm / sup -2 /与此相对应,冷却至800 / spl deg / C的样品在所有时间内均表现出90%的表观(Pb,Bi)-2223相组成,而不是(Pb,Bi)-2223从对于缓慢冷却至730 / spl deg / C的样品,随着烧结时间的增加,会增加65%至90%。由于在冷却至低于800 / spl deg / C之前的条件完全相同,因此缓慢冷却至730 / spl deg / C的样品的转化率降低必须是由于表观(Pb,Bi)- 2223相的存在温度为800 / spl deg / C。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号