Hyundai Heavy Industries Co., Ltd. (HHI) has developed a prototype of high temperature superconducting (HTS) fault current limiter (FCL) in Dec. 2006. The ratings of the HTS FCL were 13.2 kV in voltage and 630 A in current at normal condition. This HTS FCL had a HTS coil composed of 7 concentric HTS windings for current limiting element which are wound by using unique bifilar method with YBCO coated conductor (CC). The CC wound on the bobbin was insulated with Kapton tape and the HTS coil was completed assembling the windings using copper connection parts. The HTS coil was cooled down to 65 K for the enhancement of cryo-dielectric performance and critical current capacity. The short-circuit test was performed with the asymmetrical prospective fault current of 10 kA. The resistance of HTS coil began to rise up from 0.624 ms after the fault. At about 1/4 cycle after the fault, the temperature of HTS coil exceeded its critical temperature. The resistance and temperature of HTS coil after 0.1 s from the fault was calculated to be about 11.8 $Omega$ and 250 K respectively which was designed to be about 13 $Omega$ and 300 K.
机译:现代重工有限公司(HHI)于2006年12月开发了高温超导(HTS)故障电流限制器(FCL)的原型。HTSFCL的额定电压为13.2 kV,额定电流为630A。正常情况。该HTS FCL具有一个由7个同心HTS绕组组成的HTS线圈,用于限流元件,这些绕组通过使用YBCO涂层导体(CC)的独特双线法进行绕制。缠绕在绕线管上的CC用Kapton胶带绝缘,并且使用铜制连接部件完成绕组的HTS组装。将HTS线圈冷却至65 K,以增强低温介电性能和临界电流容量。在不对称预期故障电流为10 kA的情况下进行了短路测试。故障后,HTS线圈的电阻从0.624 ms开始上升。故障后约1/4个周期,高温超导线圈的温度超过其临界温度。故障后0.1 s的高温超导线圈的电阻和温度经计算分别约为11.8Ω和250 K,设计为约13Ω和300 K.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号