首页> 外文期刊>IEEE Transactions on Applied Superconductivity >Development of high temperature superconducting fault current limiting transformer (HTc-SFCLT) with Bi2212 bulk coil
【24h】

Development of high temperature superconducting fault current limiting transformer (HTc-SFCLT) with Bi2212 bulk coil

机译:带有Bi2212大容量线圈的高温超导故障限流变压器(HTc-SFCLT)的开发

获取原文
获取原文并翻译 | 示例

摘要

We have been developing a high temperature superconducting fault current limiting transformer (HTc-SFCLT) with functions of both superconducting transformer in normal operating condition and superconducting fault current limiter in fault condition. The ratings of the developed HTc SFCLT are 3-phase, 6.25 kVA, 275/105 V. The secondary coil consists of melt cast processed (MCP)-BSCCO2212/CuNi composite bulk monofilar coils, whereas the primary coil is composed of a copper coil, both of which are immersed in liquid nitrogen bath together with the iron core. Experimental results revealed the operational feasibility of HTc-SFCLT through no-load and short-circuit tests, current limiting test and recovery test.
机译:我们一直在开发一种高温超导故障限流变压器(HTc-SFCLT),该变压器具有正常工作状态下的超导变压器和故障状态下的超导故障限流器。所开发的HTc SFCLT的额定值为3,6.25 kVA,275/105V。次级线圈由熔铸加工(MCP)-BSCCO2212 / CuNi复合散装单丝线圈组成,而初级线圈由铜线圈组成,两者都与铁芯一起浸入液氮浴中。实验结果通过空载和短路测试,限流测试和恢复测试揭示了HTc-SFCLT的操作可行性。