首页> 外文期刊>Applied Superconductivity, IEEE Transactions on >Hybrid Cooling System Installation for the KEPCO HTS Power Cable
【24h】

Hybrid Cooling System Installation for the KEPCO HTS Power Cable

机译:KEPCO HTS电力电缆的混合冷却系统安装

获取原文
获取原文并翻译 | 示例

摘要

In Korea, the KEPCO (Korea Electric Power Corporation) HTS power cable system has been successfully operated for evaluating the technical and economic feasibility as well as accumulating the operation experience since 2006. A cooling system composed of a liquid nitrogen decompression cooling unit and a closed-circulation system of subcooled liquid nitrogen at the KEPCO's Gochang power testing center. As the next step, we adjusted the cooling system for the purpose of testing a different cooling system using a cryocooler unit with cooling capacity of 4 kW at 77 K in the existing cooling system. It was designed to be used as a hybrid cooling system. In other words, it has as an each system of cryocooler unit or decompression pump unit. In this paper, the performance test results are summarized and the outline of the hybrid cooling system is introduced.
机译:自2006年以来,韩国已成功运行KEPCO(韩国电力公司)HTS电力电缆系统,以评估其技术和经济可行性,并积累了运行经验。冷却系统由液氮减压冷却装置和封闭式系统组成。 KEPCO高昌电力检测中心的过冷液氮循环系统。下一步,我们调整了冷却系统,以测试使用现有冷却系统中制冷能力为4 kW(在77 K时)的冷冻机的另一种冷却系统。它被设计用作混合冷却系统。换句话说,它具有低温冷却器单元或减压泵单元的每个系统。本文总结了性能测试结果,并介绍了混合冷却系统的概况。