首页> 外文期刊>Applied Superconductivity, IEEE Transactions on >Two-Channel HTS SQUID Gradiometer System for Detection of Metallic Contaminants in Lithium-Ion Battery
【24h】

Two-Channel HTS SQUID Gradiometer System for Detection of Metallic Contaminants in Lithium-Ion Battery

机译:两通道HTS SQUID梯度仪系统,用于检测锂离子电池中的金属污染物

获取原文
获取原文并翻译 | 示例

摘要

A two-channel high-${rm T}_{rm c}$ SQUID gradiometer system for the detection of magnetic foreign matter in a lithium-ion battery was developed. Finding ultra-small metallic foreign particles can be a big issue for a manufacturer that produces commercial products such as lithium-ion batteries. If the presence of such particles is detected in its products, the manufacturer has to recall the products and thereby suffers a significant loss. Previously, we developed a detection system based on a single-channel SQUID gradiometer and horizontal magnetization. For practical use, we need to increase the detection width of the system by employing multiple sensors. In this paper, we present a two-channel high-${rm T}_{rm c}$ SQUID gradiometer system for the inspection of a lithium-ion battery. In order to increase the inspection width, two SQUID gradiometers were employed along with a specially designed cryostat. As a result, small iron particles with a diameter of less than 100 $mu{rm m}$ were detected by the system with a width of 22 mm. This is the first multi-channel high-${rm T}_{rm c}$ SQUID gradiometer system for detection of the contaminants in a lithium-ion battery.
机译:开发了一种用于检测锂离子电池中磁性异物的两通道高价SQUID梯度仪系统。对于生产商业产品(例如锂离子电池)的制造商来说,发现超细金属异物可能是一个大问题。如果在其产品中检测到此类颗粒的存在,则制造商必须召回产品,从而遭受重大损失。以前,我们开发了基于单通道SQUID梯度仪和水平磁化强度的检测系统。对于实际应用,我们需要通过使用多个传感器来增加系统的检测宽度。在本文中,我们介绍了一种用于检查锂离子电池的两通道高$ {rm T} _ {rm c} $ SQUID梯度仪系统。为了增加检查宽度,使用了两个SQUID梯度仪以及一个专门设计的低温恒温器。结果,通过宽度为22mm的系统检测到直径小于100μmrmm的小的铁颗粒。这是第一个用于检测锂离子电池中污染物的多通道高价SQUID梯度仪系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号