首页> 外文期刊>Applied Superconductivity, IEEE Transactions on >Influence of External Magnetic Field on AC Losses at EF Coil Joints of JT-60SA
【24h】

Influence of External Magnetic Field on AC Losses at EF Coil Joints of JT-60SA

机译:外部磁场对JT-60SA EF线圈接头交流损耗的影响

获取原文
获取原文并翻译 | 示例

摘要

We experimentally and numerically evaluated the AC loss occurred in joints of the EF coil in JT60-SA. There are two kinds of the joints (pancake joint and terminal joint) in the EF coil. Firstly, the AC losses of the joints were experimentally obtained. The experimental results showed that the AC losses in the pancake and the terminal joints were smaller than the loss in the prototype joint which was the previously designed joint and we measured the loss data in two years ago. And next, we numerically analysed the AC loss of the joints. The simulated results well agreed with the experimentally measured data. And we numerically tried to decrease the loss. The AC loss could be decreased to be half of the initial loss.
机译:我们通过实验和数值评估了JT60-SA中EF线圈的接头中发生的交流损耗。 EF线圈有两种接头(薄饼接头和末端接头)。首先,通过实验获得了接头的交流损耗。实验结果表明,煎饼和末端接头中的交流电损失比原型接头(以前设计的接头)中的交流电损失小,我们在两年前测量了损失数据。接下来,我们对接头的交流损耗进行了数值分析。模拟结果与实验测量数据完全吻合。而且我们在数值上试图减少损失。交流损耗可以减少到初始损耗的一半。