Japan and EU are promoting the project that the coils in JT-60 installed in Japan Atomic Energy Agency are changed to superconducting coils. We numerically and experimentally evaluate thermal stability of a conductor joint in the planning superconducting coil (EF coil). We measured an AC loss of the prototype joint, and estimated the coupling time constant. The AC loss at the EF coils joint segment was calculated based on the coupling time constant and the magnetic field distribution. Moreover, the temperature rise due to the AC loss was numerically derived. The calculation result showed that the temperature rise was small and the coil was enough stable.
机译:日本和欧盟正在推动将日本原子能机构安装的JT-60线圈更换为超导线圈的项目。我们通过数值和实验评估计划超导线圈(EF线圈)中导体接头的热稳定性。我们测量了原型接头的交流损耗,并估计了耦合时间常数。根据耦合时间常数和磁场分布,计算出EF线圈接头段的交流损耗。此外,通过数字得出了由于交流损耗引起的温度上升。计算结果表明,温升小,线圈足够稳定。