...
首页> 外文期刊>Applied clay science >One-step co-intercalation of cetyltrimethylammonium and thiourea in smectite and application of the organoclay to the sensitive electrochemical detection of Pb(Ⅱ)
【24h】

One-step co-intercalation of cetyltrimethylammonium and thiourea in smectite and application of the organoclay to the sensitive electrochemical detection of Pb(Ⅱ)

机译:蒙脱土中十六烷基三甲基铵和硫脲的一步共嵌入及有机粘土在灵敏电化学检测Pb(Ⅱ)中的应用

获取原文
获取原文并翻译 | 示例

摘要

This work describes the preparation of organoclays by one-step co-intercalation of cetyltrimethylammonium ions (CTA~+) and thiourea in various amounts within the interlayer region of smectite, and their use as electrode material for the detection of Pb(Ⅱ). The physico-chemical properties of the intercalated clay mineral were first analyzed by XRD, N_2 adsorption-desorption and FTIR. These techniques have demonstrated the successful intercalation of the modifiers in the interlayer region of the clay mineral, as evidenced by an extension of the d_(001) spacing, a decrease in porosity, and a change in FTIR patterns, all arising from the modification process. The electrochemical features and permeability properties of the organoclays, coated as thin films onto the surface of a glassy carbon electrode (GCE), were characterized through ion exchange multisweep cyclic voltammetry. Then, the organoclay film electrodes were exploited to build a sensitive and selective sensor for lead detection, thanks to the chelating ability of thiourea supported on the material. The optimal response was obtained for the functionalized clay mineral sample containing CTA~+ ions at a concentration equivalent to 25% of the CEC and thiourea in excess of the CEC of the pristine clay mineral, showing a sensitivity higher by ca. one order of magnitude with respect to the unmodified electrode. The analytical performance of the developed method was evaluated and the experimental parameters governing the preconcentration electroanalysis of lead were optimized. A linear calibration curve for Pb(Ⅱ) was obtained in the concentration range from 10~(-9) to 10~(-7) M., with a detection limit of 2.9 × 10~(-11) M (S/N = 3), which is much lower than those usually reported in the literature. The interference effects of several cations on Pb(Ⅱ) response were also evaluated, and the sensor was successfully applied to the detection of lead in tap water.
机译:这项工作描述了通过在蒙脱石层间区域内以不同数量共步插入十六烷基三甲基铵离子(CTA〜+)和硫脲制备有机粘土的方法,以及它们作为电极材料检测Pb(Ⅱ)的方法。首先通过XRD,N_2吸附-脱附和FTIR分析了插层粘土矿物的理化性质。这些技术已经证明了改性剂在粘土矿物夹层区域的成功嵌入,这是由于改性过程引起的d_(001)间距的扩大,孔隙率的降低以及FTIR图案的改变所证明的。 。通过离子交换多扫描循环伏安法表征了有机粘土的电化学特性和渗透性,这些有机粘土以薄膜形式涂覆在玻璃碳电极(GCE)的表面上。然后,由于负载在材料上的硫脲的螯合能力,有机粘土膜电极被用于构建灵敏且选择性的铅检测传感器。对于含CTA〜+离子的功能化粘土矿物样品,其浓度相当于CEC和硫脲的浓度超过原始粘土矿物的CEC的25%时,可获得最佳响应,其灵敏度约高出约55%。相对于未修饰的电极一个数量级。评价了所开发方法的分析性能,并优化了控制铅预富集电分析的实验参数。在10〜(-9)至10〜(-7)M.的浓度范围内,得到了Pb(Ⅱ)的线性校正曲线,检出限为2.9×10〜(-11)M(S / N = 3),这比文献中通常报道的要低得多。评估了几种阳离子对Pb(Ⅱ)响应的干扰作用,并将其成功应用于自来水中铅的检测。

著录项

  • 来源
    《Applied clay science 》 |2014年第9期| 297-305| 共9页
  • 作者单位

    Laboratoire de Chimie Analytique, Faculte des Sciences, Universite de Yaounde Ⅰ, B.P. 812 Yaounde, Cameroon;

    Laboratoire de Chimie Analytique, Faculte des Sciences, Universite de Yaounde Ⅰ, B.P. 812 Yaounde, Cameroon,Laboratoire de Chimie Minerale, Faculte des sciences, Universite de Dschang, B.P. 67 Dschang, Cameroon;

    Laboratoire de Chimie-Physique et Microbiologie pour l'Environnement, UMR 7564, CNRS-Universite de Lorraine, 405, rue de Vandoeuvre, F-54600 Villers-les-Nancy, France;

    Laboratoire de Chimie Analytique, Faculte des Sciences, Universite de Yaounde Ⅰ, B.P. 812 Yaounde, Cameroon;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Cetyltrimethylammonium ions; Thiourea; Organoclay film modified electrode; Lead; Electroanalysis;

    机译:十六烷基三甲基铵离子;硫脲;有机粘土膜修饰电极;铅;电分析;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号