首页> 外文期刊>分析化学 >接触燃焼式可燃性ガス検知器及びガスクロマトグラフによる温泉付随メタンガスの測定値に与える酸素濃度の影響
【24h】

接触燃焼式可燃性ガス検知器及びガスクロマトグラフによる温泉付随メタンガスの測定値に与える酸素濃度の影響

机译:催化燃烧式可燃气体检测器和气相色谱仪对氧气浓度对伴随温泉的甲烷气体测量值的影响

获取原文
获取原文并翻译 | 示例
           

摘要

2007年6月に東京都の温泉利用施設でメタン爆発死亡事rn故が発生した.兵庫県では事故直後より安全対策のためrnに,検知器法(接触燃焼式)とGC法によるメタン測定のrn検討と実態調査を行い,以下の知見を得た.%In order to prevent disasters of the explosive accidents involving methane gas associated with hot springs in Hyogo Prefecture, we examined the analysis methods of the methane, and investigated the distribution of methane in the Prefecture. We examined the analysis methods of methane by combustible gas detectors on-site and gas chromatography (GC) at a laboratory. In this study, a catalytic combustion detector was used. Results obtained from the detector method and from the GC method were compared. While measuring by a detector, when the oxygen concentration was insufficient, the deviation from the set level and the measured level was significant. However, our study revealed that by supplying oxygen through an air suction port on the detector, the influence of a low oxygen concentration could greatly be decreased. On the other hand, a measurement by the GC method was not influenced by the oxygen concentration. Methane gas levels at 104 hot spring sources in Hyogo prefecture were measured by a method combining the use of a detector and GC. The results showed that the concentration of methane was in the range between N.D. and 1560%LEL (78vol%), while the oxygen concentration was in the range from 0.01% to 17.0%. Furthermore, at 21% of the targeted hot spring sources, the methane gas concentration was found to be in excess of the standard level.
机译:2007年6月,东京的温泉设施发生了致命的甲烷爆炸。事故发生后,在兵库县,为了安全起见,通过检测器法(接触燃烧法)和气相色谱法对甲烷测量进行了检查和实际情况调查,得到了以下发现。为了防止与兵库县温泉相关的瓦斯爆炸事故的发生,我们对甲烷的分析方法进行了研究,并研究了甲烷在该地区的分布情况。通过可燃气体对甲烷的分析方法进行了研究现场检测器和实验室气相色谱仪(GC)。在本研究中,我们使用了催化燃烧检测器。比较了从检测器方法和GC方法获得的结果。不足,与设定水平和测量水平的偏差很明显,但是我们的研究表明,通过检测器上的进气口提供氧气,可以大大降低低氧气浓度的影响。气相色谱法测量不受氧气浓度的影响。兵库县104个温泉源的甲烷气体含量结果表明,甲烷浓度在ND和1560%LEL(78vol%)之间,而氧气浓度在0.01%至17.0%之间。,在目标温泉源中有21%的甲烷气体浓度超过了标准水平。

著录项

  • 来源
    《分析化学》 |2010年第2期|131-136|共6页
  • 作者单位

    兵庫県立健康生活科学研究所:652-0032 兵庫県神戸市兵庫区荒田町 2-1-29;

    兵庫県立健康生活科学研究所:652-0032 兵庫県神戸市兵庫区荒田町 2-1-29;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 jpn
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号