首页> 美国卫生研究院文献>Springer Open Choice >Enhancement of low-quality fetal electrocardiogram based on time-sequenced adaptive filtering
【2h】

Enhancement of low-quality fetal electrocardiogram based on time-sequenced adaptive filtering

机译:基于时间序列自适应滤波的低质量胎儿心电图增强

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Extraction of a clean fetal electrocardiogram (ECG) from non-invasive abdominal recordings is one of the biggest challenges in fetal monitoring. An ECG allows for the interpretation of the electrical heart activity beyond the heart rate and heart rate variability. However, the low signal quality of the fetal ECG hinders the morphological analysis of its waveform in clinical practice. The time-sequenced adaptive filter has been proposed for performing optimal time-varying filtering of non-stationary signals having a recurring statistical character. In our study, the time-sequenced adaptive filter is applied to enhance the quality of multichannel fetal ECG after the maternal ECG is removed. To improve the performance of the filter in cases of low signal-to-noise ratio (SNR), we enhance the ECG reference signals by averaging consecutive ECG complexes. The performance of the proposed augmented time-sequenced adaptive filter is evaluated in both synthetic and real data from PhysioNet. This evaluation shows that the suggested algorithm clearly outperforms other ECG enhancement methods, in terms of uncovering the ECG waveform, even in cases with very low SNR. With the presented method, quality of the fetal ECG morphology can be enhanced to the extent that the ECG might be fit for use in clinical diagnostics. >Graphical abstractThe extracted fetal ECG signals from non-invasive abdominal recordings still contain a substantial amount of noise. The time-sequenced adaptive filter provides a relatively accurate estimate of the underlying fetal ECG signal when the quality of the reference channels is enhanced prior to filtering.
机译:从无创腹部记录中提取干净的胎儿心电图(ECG)是胎儿监测的最大挑战之一。 ECG可以解释心率和心率变异性以外的心脏电活动。但是,胎儿心电图信号质量低,在临床上阻碍了其波形的形态学分析。已经提出了按时间顺序的自适应滤波器,用于对具有重复统计特性的非平稳信号进行最佳时变滤波。在我们的研究中,按时间顺序的自适应过滤器被用于提高去除母体心电图后多通道胎儿心电图的质量。为了在低信噪比(SNR)的情况下提高滤波器的性能,我们通过平均连续的ECG复数来增强ECG参考信号。在来自PhysioNet的合成数据和实际数据中都评估了所提出的增强型按时间排序的自适应滤波器的性能。此评估表明,即使在信噪比非常低的情况下,在揭示ECG波形方面,建议的算法也明显优于其他ECG增强方法。使用提出的方法,可以将胎儿ECG形态的质量提高到ECG适合用于临床诊断的程度。 <!-fig ft0-> <!-fig @ position =“ anchor” mode =文章f4-> <!-fig mode =“ anchred” f5-> >图形摘要<!-图/图片|无花果/替代品/图形模式=“锚定” m1-> <!-标题a7->从非侵入性腹部记录中提取的胎儿ECG信号仍然包含大量噪声。当在过滤之前增强参考通道的质量时,按时间顺序排列的自适应滤波器会提供相对准确的潜在胎儿ECG信号估计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号