The purpose of this study was to evaluate the one-year clinical, radiologic and patient-reported results of surface-replacing proximal interphalangeal joint arthroplasty (SR-PIP) of the hand. Fifteen patients with 18 joints underwent the procedure, and nine patients with 11 joints had follow-up of at least one year's duration. Of these joints, six had a diagnosis of osteoarthritis with no history of trauma, three had post-traumatic arthritis, one had psoriatic arthritis, and one had erosive arthritis. The mean clinical follow-up was at 3.3 years, and the mean radiographic follow-up was at 3.1 years. The average post-operative gain in range of motion at the PIP joint was 28 degrees and was statistically significant. Six patients completed self-reported questionnaires at a mean of 4.8 years post-operatively. The mean Disabilities of the Arm, Shoulder and Hand (DASH) score post-operatively was 17, and the Michigan Hand Questionnaire (MHQ) score for overall satisfaction was 70. There were three complications but only one reoperation. Seven of 11 joints showed some evidence of subsidence on follow-up radiographic examination. However, no joints were revised sec-ondary to loosening. Longer follow-up is needed to determine if this observable radiologic subsidence leads to symptomatic loosening of the implant
机译:这项研究的目的是评估手表面近端指间关节置换术(SR-PIP)的一年临床,影像学和患者报告结果。 15例18个关节的患者接受了该手术,9例11个关节的患者接受了至少一年的随访。在这些关节中,有六个诊断为无关节炎史的骨关节炎,三个为创伤后关节炎,一个为银屑病关节炎,一个为糜烂性关节炎。平均临床随访时间为3.3年,平均影像学随访时间为3.1年。 PIP关节的平均术后活动范围为28度,具有统计学意义。六名患者平均在术后4.8年完成了自我报告的调查问卷。术后平均手臂,肩膀和手部残疾(DASH)评分为17,而总体密歇根州密歇根州手调查问卷(MHQ)评分为70。有3例并发症,但只有1例再次手术。 11个关节中有7个在X线检查中显示出一些下陷的证据。但是,第二节没有任何关节松动。需要更长的随访以确定这种可观察的放射学下沉是否导致植入物症状性松动

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号