首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Accelerated Detection and Identification of Mycobacteria with MGIT 960 and COBAS AMPLICOR Systems
【2h】

Accelerated Detection and Identification of Mycobacteria with MGIT 960 and COBAS AMPLICOR Systems

机译:使用MGIT 960和COBAS AMPLICOR系统加速检测和鉴定分枝杆菌

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

An automated cultivation system for mycobacteria, the MGIT 960 system (MGIT system), was compared in the clinical routine with two variants of Löwenstein-Jensen (L-J) medium. A total of 152 isolates were recovered from 2,015 specimens: 139 (91%) with the MGIT system and 127 (84%) with L-J media (P = 0.05). These included 68 isolates of Mycobacterium tuberculosis, of which 88% grew in the MGIT system and 93% grew in L-J media (P = 0.389), and 84 isolates of mycobacteria other than M. tuberculosis (MOTT), of which 94% grew in the MGIT system and 76% grew in L-J media (P = 0.003). More M. avium complex isolates were detected in the MGIT system (n = 65) than in L-J media (n = 50) (P = 0.001). Growth in the MGIT system was detected in 2 weeks for 78% of the isolates, whereas growth was detected in the two L-J media for 17 and 25% of the isolates, respectively. The mean times to detection of M. tuberculosis were 12 days in the MGIT system and 20 days in L-J media, and for M. avium complex the mean times to detection were 8 and 22 to 25 days, respectively. The contamination rates were similar (8.7 to 8.9%) in all media. A commercial amplification system (COBAS AMPLICOR) was evaluated for its ability to rapidly identify M. tuberculosis, M. avium, and M. intracellulare directly from 393 samples in MGIT system broth. A correct PCR result, as evaluated by culture or clinical data, was obtained for 96% of the samples, with inhibition being detected for 2% of the samples. Of the 89 results positive for M. tuberculosis, 91% were regarded as true positive, 8% were regarded as inconclusive, and 2% were considered false positive. For results positive for M. avium and M. intracellulare, 97 and 79%, respectively, were regarded as true positive. Increased rapidity and enhanced isolation of MOTT were obtained with the MGIT system. COBAS AMPLICOR was suitable for rapid identification of these three common pathogens from MGIT system broth.
机译:在临床常规中,使用Löwenstein-Jensen(L-J)培养基的两种变体比较了分枝杆菌的自动培养系统MGIT 960系统(MGIT系统)。从2,015个标本中总共回收了152个分离株:MGIT系统为139个(91%),L-J培养基为127个(84%)(P = 0.05)。其中包括68株结核分枝杆菌,其中88%在MGIT系统中生长,93%在LJ培养基中生长(P = 0.389),以及84株除结核分枝杆菌(MOTT)以外的分枝杆菌,其中94%在结核分枝杆菌中生长。 MGIT系统,其中76%在LJ媒体中增长(P = 0.003)。在MGIT系统(n = 65)中检测到的鸟分枝杆菌复杂分离物比在L-J培养基(n = 50)中检测到的更多(P = 0.001)。 MGIT系统在2周内检测到78%的分离株生长,而在两种L-J培养基中分别检测到17%和25%的生长。在MGIT系统中,检测结核分枝杆菌的平均时间为12天,在L-J培养基中为20天,而对于鸟分枝杆菌复合体,平均检测时间分别为8天和22至25天。在所有培养基中,污染率相似(8.7%至8.9%)。对商用扩增系统(COBAS AMPLICOR)进行了评估,该系统可直接从MGIT系统肉汤中的393个样品中快速鉴定结核分枝杆菌,鸟分枝杆菌和胞内分枝杆菌。通过培养或临床数据评估得出正确的PCR结果,适用于96%的样品,其中2%的样品被抑制。在结核分枝杆菌阳性的89个结果中,有91%被认为是真实阳性,有8%被认为没有结论,有2%被认为是假阳性。对于鸟分枝杆菌和 M阳性的结果。细胞内阳性率分别为97%和79%。 MGIT系统提高了MOTT的速度并提高了隔离度。 COBAS AMPLICOR适用于从MGIT系统肉汤中快速鉴定这三种常见病原体。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号