首页> 美国卫生研究院文献>Journal of Clinical Microbiology >GEMHEP multicenter quality control study of PCR detection of GB virus C/hepatitis G virus RNA in serum.
【2h】

GEMHEP multicenter quality control study of PCR detection of GB virus C/hepatitis G virus RNA in serum.

机译:PCR检测血清中GB丙型肝炎病毒/ G型肝炎病毒RNA的GEMHEP多中心质量控制研究。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

PCR is, to date, the only available tool for the detection of GB virus C (GBV-C) and hepatitis G virus (HGV) RNAs. Twenty-two French laboratories participated in a quality control study to assess the sensitivity and specificity of their procedures. The panel included 13 positive controls and 7 negative controls. The laboratories used either in-house PCR techniques adapted from the literature or partly standardized commercial tests. Three laboratories performed faultlessly with the entire panel. Most laboratories had excellent specificity (100% in 20 of 22 laboratories). Sensitivity was acceptable (85 to 100%) in 15 centers and insufficient (38 to 77%) in 7. As with nonstandardized in-house PCR, the commercial assays gave discrepant performances in different laboratories. These results suggest that laboratories willing to use PCR for detection of GBV-C/HGV RNA for research or diagnostic purposes should participate in multicenter quality control trials.
机译:迄今为止,PCR是唯一可用于检测GB病毒C(GBV-C)和G肝炎病毒(HGV)RNA的工具。 22个法国实验室参加了质量控制研究,以评估其程序的敏感性和特异性。小组包括13个阳性对照和7个阴性对照。实验室使用从文献改编的内部PCR技术或部分标准化的商业测试。三个实验室对整个面板进行了完美的测试。大多数实验室具有出色的特异性(22个实验室中有20个实验室的特异性为100%)。在15个中心的灵敏度是可接受的(85%至100%),而在7个中心的灵敏度是不足(38%至77%)。与非标准化的内部PCR一样,商业化验在不同实验室中的表现也不尽相同。这些结果表明,愿意将PCR用于检测GBV-C / HGV RNA以进行研究或诊断的实验室应参加多中心质量控制试验。

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号