首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Fluorescent monoclonal antibody compared with carbohydrate utilization for rapid identification of Neisseria gonorrhoeae.
【2h】

Fluorescent monoclonal antibody compared with carbohydrate utilization for rapid identification of Neisseria gonorrhoeae.

机译:荧光单克隆抗体与碳水化合物利用相比可快速鉴定淋病奈瑟氏球菌。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A commercially available fluorescein-conjugated monoclonal antibody (MAb) (Syva Co., Palo Alto, Calif.; Genetic Systems, Seattle, Wash.) against Neisseria gonorrhoeae was compared with a standard cystine Trypticase agar (CTA) sugar utilization method and with three rapid carbohydrate utilization tests, including the Minitek (BBL Microbiology Systems, Cockeysville, Md.), Neisseria-Stat (Richardson Scientific, Dallas, Tex.), and Neisseria-Kwik (Micro-Biologics, St. Cloud, Minn.) systems for the identification of Neisseria species. The MAb correctly identified all 86 clinical isolates of N. gonorrhoeae. Of these 86 isolates, 28 were found later (48 h after the initial inoculation) to be contaminated with non-Neisseria bacteria. In the other four test systems studied, the identification rates for pure and contaminated N. gonorrhoeae cultures were, respectively, as follows: CTA sugars, 88 and 32%; Minitek, 67 and 50%; Neisseria-Stat, 97 and 96%; and Neisseria-Kwik, 80 and 74%. The MAb did not identify any of the 50 nongonoccocal Neisseria isolates tested. The most expensive test system was the MAb, followed by the Neisseria-Kwik, Minitek, Neisseria-Stat, and CTA sugars systems. The MAb appears to be a rapid and accurate method to identify in vitro isolates of N. gonorrhoeae.
机译:将市售的针对淋病奈瑟氏球菌的荧光素偶联单克隆抗体(MAb)(Syva Co.,加利福尼亚州帕洛阿尔托; Genetic Systems,西雅图,华盛顿)与标准胱氨酸胰蛋白酶(CTA)琼脂糖(CTA)糖利用方法和三种方法进行了比较。快速碳水化合物利用测试,包括用于以下系统的Minitek(BBL Microbiology系统,马里兰州科基斯维尔),Neisseria-Stat(Richardson Scientific,德克萨斯州达拉斯)和Neisseria-Kwik(Micro-Biologics,圣克劳德,明尼苏达州)系统奈瑟菌属的鉴定。 MAb正确鉴定了淋病奈瑟氏球菌的所有86种临床分离株。在这86株分离株中,有28株在最初接种后48小时后被非奈瑟氏菌污染。在研究的其他四个测试系统中,纯净和污染的淋病奈瑟球菌培养物的鉴定率分别为:CTA糖分别为88%和32%; Minitek,67%和50%; Neisseria-Stat,分别为97%和96%; Neisseria-Kwik分别为80%和74%。 MAb没有鉴定出所测试的50种非淋球菌奈瑟菌分离物中的任何一种。最昂贵的测试系统是MAb,其次是Neisseria-Kwik,Minitek,Neisseria-Stat和CTA制糖系统。 MAb似乎是鉴定淋病奈瑟菌体外分离物的快速而准确的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号