首页> 美国卫生研究院文献>other >Sources of variation in flow cytometric analysis of aquatic species sperm: The effect of cryoprotectants on flow cytometry scatter plots and subsequent population gating
【2h】

Sources of variation in flow cytometric analysis of aquatic species sperm: The effect of cryoprotectants on flow cytometry scatter plots and subsequent population gating

机译:水生物种精子流式细胞术分析的变异源:冷冻保护剂对流式细胞术散射地块和随后人口门控的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The use of fluorescent staining and flow cytometry to assess sperm quality in aquatic species has increased over the past decade, but comparisons among studies are difficult or impossible due to variation in application, analysis, and reporting of protocols and data.The goal of the present study was to determine the effect of exposure to two cryoprotectants commonly used for cryopreservation of sperm from aquatic species on the accuracy of flow cytometric assessment of sperm quality.Membrane integrity of zebrafish (Danio rerio) sperm exposed to 10% and 20%methanol and dimethyl sulfoxide (DMSO)in 300 mOsm kg−1 Hanks’ balanced salt solution (HBSS) or calcium-free HBSSwas determined using SYBR 14/propidium iodide staining. Both cryoprotectants significantly affected forward-scatter and side-scatter characteristics of sperm samples, resulting in significant changes in the number of total and gated events, and in the number and percentage of intact cells. These results indicate that it cannot be assumed that the approach to flow cytometric analysis of fresh sperm will be applicable to cryoprotectant-treated or cryopreserved sperm. In total, we document examples of five potentially interacting factors that produce errors of 5 to 50% each, resulting in underestimates and overestimates of total and intact sperm (actual numbers and percentages) in the presence of the two most commonly used cryoprotectants at the concentrations used most often for cryopreservation of sperm from aquatic species. This study provides methods to reduce or eliminate these errors and recommendations necessary for standardization and reporting.
机译:在过去的十年中,使用荧光染色和流式细胞仪评估水生物种精子质量的情况有所增加,但是由于应用,分析以及方案和数据的报告存在差异,因此很难或不可能进行研究之间的比较。这项研究旨在确定暴露于两种常用于水生物种精子冷冻保存的冷冻保护剂对流式细胞术评估精子质量准确性的影响。斑马鱼(Danio rerio)精子的膜完整性暴露于10%和20%的甲醇和二甲基在300 mOsm kg -1 Hanks平衡盐溶液(HBSS)或无钙HBSSwas中使用SYBR 14 /碘化丙啶染色测定亚砜(DMSO)。两种冷冻保护剂均会显着影响精子样本的前向散射和侧向散射特性,从而导致总事件和门控事件的数量以及完整细胞的数量和百分比发生显着变化。这些结果表明,不能假设新鲜精子的流式细胞术分析方法将适用于冷冻保护剂处理或冷冻保存的精子。总的来说,我们记录了五个潜在相互作用因素的示例,这些因素在每种浓度下存在两种最常用的冷冻保护剂时,都会产生5%至50%的误差,导致精子总数和完整精子(实际数量和百分比)的低估和高估。最常用于冷冻保存水生物种精子的过程。这项研究提供了减少或消除这些错误的方法以及标准化和报告所必需的建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号