Reliability and reproducibility of spectral and time domain optical coherence tomography images before and after correction for patients with age-related macular degeneration

机译:年龄相关性黄斑变性患者校正前后的光谱和时域光学相干断层扫描图像的可靠性和可重复性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Purpose: To evaluate the reproducibility and reliability of optical coherence tomography scans obtained using the time domain (TD-OCT) Stratus TM OCT, and the Spectral Domain (SD-OCT) Spectralis TM and Cirrus TM OCT devices before and after manual correction in eyes with either Neovascular (NV-AMD) or Non-Neovascular (NNV-AMD) age-related macular degeneration. >Design: Prospective observational study. >Methods: Setting: University-based retina practice. Patients: Thirty-six patients (50 eyes) with NV-AMD or NNV-AMD. Procedure: OCT scans were taken simultaneously using one TD-OCT and two SD-OCT devices. Main Outcome Measures: Macular thickness measurements were assessed before and after correction of the algorithm by constructing Bland-Altman plots for agreement and calculating intraclass correlation coefficients (ICCs) and coefficients of repeatability (COR) to evaluate intraclass repeatability. >Results: Spectralis had the highest number of images needing manual correction.  All machines had high ICCs, with Spectralis having the highest.  Also, Bland-Altman plots indicated that there was low agreement between Cirrus™ and Stratus™, Spectralis™ and Stratus™, while there was good agreement between the Cirrus™ and Spectralis™.  The CORs were lowest for Spectralis TM and similar and higher for Cirrus TM and Stratus TM.  Agreement, CORs, and ICCs generally improved after manual correction, but only minimally.  >Conclusion: Agreement is low between devices, except between both SD-OCT machines.  Manual correction tends to improve results.
机译:>目的:评价使用时域(TD-OCT)Stratus TM OCT和光谱域(SD-OCT)获得的光学相干断层扫描的可重复性和可靠性在年龄相关性黄斑变性的新生血管(NV-AMD)或非新生血管(NNV-AMD)的眼睛中进行手动矫正之前和之后,Spectralis TM 和Cirrus TM OCT设备。 >设计:前瞻性观察研究。 >方法:设置:基于大学的视网膜实践。患者:36例(50眼)NV-AMD或NNV-AMD患者。程序:使用一台TD-OCT和两台SD-OCT设备同时进行OCT扫描。主要结果测量:在校正算法前后,通过建立Bland-Altman图以达成一致并计算组内相关系数(ICC)和重复性系数(COR)来评估组内重复性,评估了黄斑厚度测量。 >结果: Spectralis的图像数量最多,需要手动校正。所有机器的ICC都很高,其中Spectralis的ICC最高。而且,Bland-Altman图表明Cirrus™和Stratus™,Spectralis™和Stratus™之间的一致性较低,而Cirrus™和Spectralis™之间的一致性较高。 Spectralis TM 的COR最低,而Cirrus TM 和Stratus TM 的COR较高。手动更正后,一致性,COR和ICC通常会有所改善,但仅有很小的改善。 >结论:设备之间的协议很少,除了两台SD-OCT机器之间。手动校正会改善结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号