We present an algorithm to automatically estimate the diameter of the optic nerve sheath from ocular ultrasound images. The optic nerve sheath diameter provides a proxy for measuring intracranial pressure, a life threating condition frequently associated with head trauma. Early treatment of elevated intracranial pressures greatly improves outcomes and drastically reduces the mortality rate. We demonstrate that the proposed algorithm combined with a portable ultrasound device presents a viable path for early detection of elevated intracranial pressure in remote locations and without access to trained medical imaging experts.
机译:我们提出了一种算法,可以从眼部超声图像自动估计视神经鞘管的直径。视神经鞘管的直径可以用来测量颅内压,颅内压是一种经常与头部创伤相关的威胁生命的疾病。颅内压升高的早期治疗可大大改善预后并大大降低死亡率。我们证明,提出的算法与便携式超声设备相结合,为早期发现偏远地区的颅内压升高提供了一条可行的途径,并且无需经过培训的医学影像专家。