Acute mechanical damage and the resulting joint contact abnormalities are central to the initiation and progression of post-traumatic osteoarthritis (PTOA). Study of PTOA is typically performed in vivo with replicate animals using artificially induced injury features. The goal of this work was to measure changes in a joint contact stress in the knee of a large quadruped after creation of a clinically realistic overload injury and a focal cartilage defect. Whole-joint overload was achieved by excising a 5-mm wedge of the anterior medial meniscus. Focal cartilage defects were created using a custom pneumatic impact gun specifically developed and mechanically characterized for this work. To evaluate the effect of these injuries on joint contact mechanics, Tekscan (Tekscan, Inc., South Boston, MA) measurements were obtained pre-operatively, postmeniscectomy, and postimpact (1.2-J) in a nonrandomized group of axially loaded cadaveric sheep knees. Postmeniscectomy, peak contact stress in the medial compartment is increased by 71% (p = 0.03) and contact area is decreased by 35% (p = 0.001); the center of pressure (CoP) shifted toward the cruciate ligaments in both the medial (p = 0.004) and lateral (p = 0.03) compartments. The creation of a cartilage defect did not significantly change any aspect of contact mechanics measured in the meniscectomized knee. This work characterizes the mechanical environment present in a quadrupedal animal knee joint after two methods to reproducibly induce joint injury features that lead to PTOA.
机译:急性机械损伤和由此引起的关节接触异常是创伤后骨关节炎(PTOA)发生和发展的关键。 PTOA的研究通常是使用人工诱导的损伤特征在复制动物体内进行的。这项工作的目的是测量在临床上切合实际的过载损伤和局灶性软骨缺损后,一个大四足动物的膝盖的关节接触应力的变化。通过切除内侧前半月板的5毫米楔形物实现全关节超负荷。使用专门为这项工作开发并具有机械特性的定制气动冲击枪可产生局部软骨缺损。为了评估这些损伤对关节接触力学的影响,在非随机组的轴向负载尸体绵羊膝盖的术前,半月板切除术和撞击后(1.2-J)进行了Tekscan(Tekscan,Inc.,South Boston,MA)的测量。 。半月板切除术后,内侧腔室的峰值接触应力增加了71%(p = 0.03),接触面积减少了35%(p = 0.001);压力中心(CoP)向内侧(p = 0.004)和外侧(p = 0.03)的交叉韧带转移。软骨缺损的产生并没有显着改变在半月板切除的膝盖中测得的接触力学的任何方面。这项工作表征了通过两种方法可再现地诱发导致PTOA的关节损伤特征后,四足动物膝关节中存在的机械环境。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号