首页> 美国卫生研究院文献>Journal of Analytical Toxicology >High-Performance Liquid Chromatography with Tandem Mass Spectrometry for the Determination of Nine Hallucinogenic 25-NBOMe Designer Drugs in Urine Specimens
【2h】

High-Performance Liquid Chromatography with Tandem Mass Spectrometry for the Determination of Nine Hallucinogenic 25-NBOMe Designer Drugs in Urine Specimens

机译:高效液相色谱-串联质谱法测定尿样中的九种致幻剂25-NBOMe设计药物

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We present a high-performance liquid chromatography triple quadrupole mass spectrometry (HPLC–MS-MS) method for the identification and quantification of nine serotonin 5-HT2A receptor agonist hallucinogenic substances from a new class of N-methoxybenzyl derivatives of methoxyphenylethylamine (NBOMe) designer drugs in human urine: 25H-NBOMe, 2CC-NBOMe, 25I-NBF, 25D-NBOMe, 25B-NBOMe, 2CT-NBOMe, 25I-NBMD, 25G-NBOMe and 25I-NBOMe. This assay was developed for the Virginia Commonwealth University Clinical and Forensic Toxicology laboratory to screen emergency department specimens in response to an outbreak of N-benzyl-phenethylamine derivative abuse and overdose cases in Virginia. The NBOMe derivatives were rapidly extracted from the urine specimens by use of FASt™ solid-phase extraction columns. Assay performance was determined as recommended for validation by the Scientific Working Group for Forensic Toxicology (SWGTOX) for linearity, lower limit of quantification, lower limit of detection, accuracy/bias, precision, dilution integrity, carryover, selectivity, absolute recovery, ion suppression and stability. Linearity was verified to be from 1 to 100 ng/mL for each of the nine analytes. The bias determined for the NBOMe derivatives was 86–116% with a <14% coefficient of variation over the linear range of the assay. Four different NBOMe derivatives were detected using the presented method in patient urine specimens.
机译:我们提出了一种高效液相色谱三重四极杆质谱(HPLC-MS-MS)方法,用于从新型N-甲氧基苯基乙胺(NBOMe)的N-甲氧基苄基衍生物中鉴定和定量九种5-羟色胺5-HT2A受体激动剂致幻物质。人尿中的药物:25H-NBOMe,2CC-NBOMe,25I-NBF,25D-NBOMe,25B-NBOMe,2CT-NBOMe,25I-NBMD,25G-NBOMe和25I-NBOMe。该测定法是为弗吉尼亚联邦大学临床和法医毒理学实验室开发的,用于筛查急诊室标本,以应对弗吉尼亚州爆发的N-苄基-苯乙胺衍生物滥用和药物过量案件。使用FASt™固相萃取柱可快速从尿液样本中萃取NBOMe衍生物。根据法医毒理学科学工作组(SWGTOX)的建议,确定测定性能,以确保其线性,定量下限,检测下限,准确度/偏差,精密度,稀释完整性,残留,选择性,绝对回收率,离子抑制率和稳定性。九种分析物的线性均被证实为1至100 ng / mL。为NBOMe衍生物确定的偏差为86–116%,在测定的线性范围内变异系数小于14%。使用本方法在患者尿液样本中检测到四种不同的NBOMe衍生物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号