This study explored drug release from paclitaxel + hirudin-eluting balloons in a healthy pig coronary artery model and objectively evaluated the vascular reactivity after balloon intervention. A total of 12 healthy white pigs were used for the analysis of drug release from the experimental balloon. The observational time-points included immediately following implantation and day 7, 30, and 180 after surgery. At each time-point, two pigs were treated with the paclitaxel + hirudin-eluting balloon and one with the B. Braun paclitaxel-eluting balloon (control). Quantitative coronary angiography (QCA) of the target vessel was performed before and after balloon treatment. One pig died before the designated experimental endpoint, and no abnormal clinical signs or tissue lesions were observed in the other pigs. QCA showed different degrees of spasms after balloon treatment, all of which recovered shortly thereafter without intervention. The blood vessel lumens were all open and without dissection or angioma. Drug content determination showed that the experimental balloon performed better than the control balloon with regard to drug release, vascular absorption and expulsion rate. The paclitaxel + hirudin-eluting balloon catheter was easy to manipulate. The drug release from the experimental balloon was stable and resulted in good vascular reactivity. The safety and efficacy of the experimental balloon were not worse than the paclitaxel-eluting balloon that is currently on the market.
机译:这项研究探索了健康猪冠状动脉模型中紫杉醇+水+素洗脱球囊的药物释放,并客观评估了球囊干预后的血管反应性。总共12只健康的白猪用于分析从实验气球释放的药物。观察时间点包括植入后立即以及手术后第7、30和180天。在每个时间点,用紫杉醇+水rud素洗脱球囊治疗两只猪,用B. Braun紫杉醇洗脱球囊治疗一只猪(对照)。在球囊治疗之前和之后进行目标血管的定量冠状动脉造影(QCA)。一头猪在指定的实验终点之前死亡,另一只猪没有观察到异常的临床体征或组织损伤。 QCA在气囊治疗后表现出不同程度的痉挛,此后不久无需干预即可全部恢复。血管腔全部开放,无解剖或血管瘤。药物含量的测定表明,在药物释放,血管吸收和排出速率方面,实验球囊的表现优于对照球囊。紫杉醇+水rud素洗脱球囊导管易于操作。从实验球囊释放的药物是稳定的,并导致良好的血管反应性。实验气球的安全性和功效不比目前市场上的紫杉醇洗脱气球差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号