Accuracy of Blood Loss Measurement during Cesarean Delivery

机译:剖宫产术中失血量测量的准确性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Objective This study aims to compare the accuracy of visual, quantitative gravimetric, and colorimetric methods used to determine blood loss during cesarean delivery procedures employing a hemoglobin extraction assay as the reference standard. >Study Design In 50 patients having cesarean deliveries blood loss determined by assays of hemoglobin content on surgical sponges and in suction canisters was compared with obstetricians' visual estimates, a quantitative gravimetric method, and the blood loss determined by a novel colorimetric system. Agreement between the reference assay and other measures was evaluated by the Bland–Altman method. >Results Compared with the blood loss measured by the reference assay (470 ± 296 mL), the colorimetric system (572 ± 334 mL) was more accurate than either visual estimation (928 ± 261 mL) or gravimetric measurement (822 ± 489 mL). The correlation between the assay method and the colorimetric system was more predictive (standardized coefficient = 0.951, adjusted R2 = 0.902) than either visual estimation (standardized coefficient = 0.700, adjusted R2 = 00.479) or the gravimetric determination (standardized coefficient = 0.564, adjusted R2 = 0.304). >Conclusion During cesarean delivery, measuring blood loss using colorimetric image analysis is superior to visual estimation and a gravimetric method. Implementation of colorimetric analysis may enhance the ability of management protocols to improve clinical outcomes.
机译:>目的本研究旨在比较采用血红蛋白提取测定作为参考标准的剖腹产过程中用于确定失血量的视觉,定量重量和比色方法的准确性。 >研究设计将通过分析手术海绵和吸罐中的血红蛋白含量确定的50例剖宫产失血患者与产科医生的视觉估计,定量重量法进行比较,并通过剖宫产术确定失血量。新型比色系统。参考试验与其他措施之间的一致性通过Bland–Altman方法进行了评估。 >结果比色系统(572±334 mL)与参考测定(470±296 mL)的失血量相比,目测估计(928±261 mL)或重量法测量的准确度更高(822±489mL)。与任一目测估计(标准系数= 0.700,调整后的R 2 2 = 0.902)。 sup> = 00.479)或重量测定法(标准系数= 0.564,调整后的R 2 = 0.304)。 >结论在剖宫产过程中,使用比色图像分析测量失血量要优于视觉估计和重量分析法。比色分析的实施可以增强管理协议改善临床结果的能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号