We present a case with aortic rupture during an operation of thoracic endovascular aortic repair of an anastomotic pseudoaneurysm. This happened after the use of a low-pressure remodeling balloon inside the covered part of the deployed endografts. It was successfully treated with a second more centrally in the aortic arch-implanted endograft with full coverage of the left subclavian artery orifice. This patient had a history of surgically operated aortic coarctation.
机译:我们提出一个吻合器假性动脉瘤的胸腔内血管主动脉修复手术中主动脉破裂的病例。这是在已部署的内移植物的覆盖部分内部使用低压重塑气球之后发生的。在主动脉弓植入的内植体中更成功地进行了第二次更彻底的治疗,完全覆盖了左锁骨下动脉孔。该患者有手术主动脉缩窄的病史。