首页> 美国卫生研究院文献>Biophysical Journal >Direct measurement of the concentration- and time-dependent open probability of the nicotinic acetylcholine receptor channel.
【2h】

Direct measurement of the concentration- and time-dependent open probability of the nicotinic acetylcholine receptor channel.

机译:直接测量烟碱乙酰胆碱受体通道的浓度和时间依赖性开放概率。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Using the outside-out patch clamp recording technique together with a rapid solution exchange system, we measured ionic currents through nicotinic acetylcholine (ACh) receptor channels from BC3H-1 cells in response to rapid applications of 0.3-1,000 microM ACh. We used nonstationary fluctuation analysis of ensembles of responses to deduce the number of channels in the patch, the maximum open channel probability as a function of ACh concentration and the time course of a fast desensitization process. We found that: (a) Excised patches from BC3H-1 cells typically contain between 50 and 150 functional ACh receptor ion channels. (b) The open channel probability is proportional to [ACh]1.95 at low concentrations of ACh, is half-maximal at 20 microM ACh and saturates above 100 microM ACh. (c) ACh is a very efficacious agonist; 100 microM ACh opens at least 90% of the available channels. This estimate of efficacy is model-independent. (d) The rate of decay of the agonist-induced current is concentration-dependent. In the presence of 100 microM ACh the current decays with a time constant of 50-100 ms. It decays more slowly in the presence of lower concentrations of agonist but is relatively insensitive to voltage.
机译:使用由外而外的膜片钳记录技术和快速溶液交换系统,我们测量了响应于0.3-1,000 microM ACh的快速应用,来自BC3H-1细胞的烟碱乙酰胆碱(ACh)受体通道的离子电流。我们使用响应集合的非平稳波动分析来推导贴片中的通道数,最大开放通道概率与ACh浓度的关系以及快速脱敏过程的时间过程。我们发现:(a)从BC3H-1细胞切除的补丁通常包含50至150个功能性ACh受体离子通道。 (b)在低浓度的ACh中,开路概率与[ACh] 1.95成比例,在20 microM ACh时为最大,在100 microM ACh以上时饱和。 (c)ACh是一种非常有效的激动剂; 100 microM ACh至少打开90%的可用通道。疗效的估计与模型无关。 (d)激动剂感应电流的衰减速率取决于浓度。在存在100 microM ACh的情况下,电流以50-100 ms的时间常数衰减。在较低浓度的激动剂存在下,它的衰减更慢,但对电压相对不敏感。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号