首页> 美国卫生研究院文献>Journal of Physical Therapy Science >Intra-rater and Inter-rater Reliability of Mandibular Range of MotionMeasures Considering a Neutral Craniocervical Position
【2h】

Intra-rater and Inter-rater Reliability of Mandibular Range of MotionMeasures Considering a Neutral Craniocervical Position

机译:下颌运动范围的评定者内和评定者间可靠性考虑中性颅颈位置的措施

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

[Purpose] The aim of this study was to determine the inter-rater and intra-rater reliability of the mandibular range of motion (ROM) considering the neutral craniocervical position when performing the measurements. [Subjects and Methods] The sample consisted of 50 asymptomatic subjects. Two raters measured four mandibular ROMs (maximal mouth opening (MMO), laterals, and protrusion) using the craniomandibular scale. Subjects alternated between raters, receiving two complete trials per day, two days apart. Intra- and inter-rater reliability was determined using intra-class correlation coefficients (ICCs). Bland-Altman analysis was used to assess reliability, bias, and variability. Finally, the standard error of measurement (SEM) and minimal detectable change (MDC) were analyzed to measure responsiveness. [Results] Reliability was good for MMO (inter-rater, ICC= 0.95−0.96; intra-rater, ICC= 0.95−0.96) and for protrusion (inter-rater, ICC= 0.92−0.94; intra-rater, ICC= 0.93−0.96). Reliability was moderate for lateral excursions. The MMO and protrusion SEM ranged from 0.74 to 0.82 mm and from 0.29 to 0.49 mm, while the MDCs ranged from 1.73 to 1.91 mm and from 0.69 to 0.14 mm respectively. The analysis showed no random or systematic error, suggesting that effect learning did not affect reliability. [Conclusion] A standardized protocol for assessment of mandibular ROM in a neutral craniocervical position obtained good inter- and intra-rater reliability for MMO andprotrusion and moderate inter- and intra-rater reliability for lateral excursions.
机译:[目的]本研究的目的是确定在进行测量时考虑中性颅颈位置的下颌运动范围(ROM)的评定者间和评定者内可靠性。 [受试者和方法]样本由50名无症状受试者组成。两名评估者使用颅下颌骨量表测量了四个下颌ROM(最大张口(MMO),外侧和突出)。受试者在评估者之间交替,每天接受两次完整的试验,相隔两天。使用类内相关系数(ICC)确定评估者内部和评估者之间的可靠性。使用Bland-Altman分析来评估可靠性,偏差和变异性。最后,分析了标准测量误差(SEM)和最小可检测变化(MDC)以测量响应度。 [结果] MMO(内部评估者,ICC = 0.95-0.96;内部评估者,ICC = 0.95-0.96)和突出(内部评估者,ICC = 0.92-0.94;内部评估者,ICC = 0.93)的可靠性良好-0.96)。侧向偏移的可靠性中等。 MMO和突起SEM的范围分别为0.74至0.82mm和0.29至0.49mm,而MDC的范围分别为1.73至1.91mm和0.69至0.14mm。分析显示没有随机或系统错误,表明效果学习不会影响可靠性。 [结论]评估中性颅颈位下颌ROM的标准化协议在MMO和突出和适度的评估者内部和评估者之间的横向偏移。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号