The objectives of the study were to determine the validity and reliability of peak velocity (PV), average velocity (AV), peak power (PP) and average power (AP) measurements were made using a linear position transducer. Validity was assessed by comparing measurements simultaneously obtained using the Tendo Weightlifting Analyzer Systemi and T-Force Dynamic Measurement Systemr (Ergotech, Murcia, Spain) during two resistance exercises, bench press (BP) and full back squat (BS), performed by 71 trained male subjects. For the reliability study, a further 32 men completed both lifts using the Tendo Weightlifting Analyzer Systemz in two identical testing sessions one week apart (session 1 vs. session 2). Intraclass correlation coefficients (ICCs) indicating the validity of the Tendo Weightlifting Analyzer Systemi were high, with values ranging from 0.853 to 0.989. Systematic biases and random errors were low to moderate for almost all variables, being higher in the case of PP (bias ±157.56 W; error ±131.84 W). Proportional biases were identified for almost all variables. Test-retest reliability was strong with ICCs ranging from 0.922 to 0.988. Reliability results also showed minimal systematic biases and random errors, which were only significant for PP (bias -19.19 W; error ±67.57 W). Only PV recorded in the BS showed no significant proportional bias. The Tendo Weightlifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and estimating power in resistance exercises. The low biases and random errors observed here (mainly AV, AP) make this device a useful tool for monitoring resistance training.Key points class="unordered" style="list-style-type:disc">This study determined the validity and reliability of peak velocity, average velocity, peak power and average power measurements made using a linear position transducerThe Tendo Weight-lifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and power.
机译:该研究的目的是确定使用线性位置传感器进行的峰值速度(PV),平均速度(AV),峰值功率(PP)和平均功率(AP)测量的有效性和可靠性。通过比较使用Tendo举重分析仪Systemi和T-Force动态测量系统(Ergotech,西班牙穆尔西亚)在两个阻力练习(卧推(BP)和后坐深蹲(BS))中同时获得的测量值来评估有效性,该运动由71名受过训练的人进行男性对象。为了进行可靠性研究,另外32名人员使用Tendo举重分析仪Systemz在两个相同的测试环节中完成了两次举重,每星期一次(会话1对会话2)。表示Tendo举重分析仪Systemi有效性的类内相关系数(ICC)高,范围在0.853至0.989之间。几乎所有变量的系统偏差和随机误差均从低到中等,在PP情况下则更高(偏差±157.56 W;误差±131.84 W)。几乎所有变量都确定了比例偏差。 ICC范围从0.922至0.988的重测可靠性很强。可靠性结果还显示出最小的系统偏差和随机误差,这仅对PP有效(偏置-19.19 W;误差±67.57 W)。仅记录在BS中的PV没有明显的比例偏差。 Tendo举重分析仪Systemi成为一种可靠的系统,可用于测量运动速度和估算阻力练习中的力量。此处观察到的低偏差和随机误差(主要是AV,AP)使该设备成为监视阻力训练的有用工具。要点 class =“ unordered” style =“ list-style-type:disc”> <!- list-behavior = unordered prefix-word = mark-type = disc max-label-size = 0-> 本研究确定了使用A进行的峰值速度,平均速度,峰值功率和平均功率测量的有效性和可靠性线性位置传感器 Tendo举重分析仪系统i成为测量运动速度和功率的可靠系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号