首页> 美国卫生研究院文献>Craniomaxillofacial Trauma Reconstruction >The Use of 2.4-mm Locking Plate System in Treating Comminuted Mandibular Fracture by Firearm
【2h】

The Use of 2.4-mm Locking Plate System in Treating Comminuted Mandibular Fracture by Firearm

机译:2.4 mm锁定板系统在枪械粉碎性下颌骨折治疗中的应用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Maxillofacial trauma caused by firearms has considerably increased, in which the mandibular body is the site of highest incidence of firearm projectiles. In these cases, the use of titanium plates and screws allows the early restoration of form and function of the mandible with stable and predictable results. Recently, conventional plates have been extensively used to treat comminuted mandibular fractures. Nevertheless, the conventional system presents several limitations such as screw compression against the bone interface and the necessity of precise fit of plate to the bone. To overcome such drawbacks, the locking plates have emerged. The present clinical case reported the operative treatment of mandibular fracture caused by firearm projectiles with the use of locking plate. The indications, advantages, and disadvantages of this system are presented.
机译:枪支造成的颌面创伤已大大增加,其中下颌体是枪支弹丸发病率最高的地点。在这种情况下,钛板和螺钉的使用可以尽早恢复下颌骨的形状和功能,并获得稳定和可预测的结果。最近,传统的钢板已被广泛用于治疗下颌粉碎性骨折。然而,常规系统存在一些局限性,例如对骨界面的螺钉压缩以及板与骨精确配合的必要性。为了克服这些缺点,出现了锁定板。本临床病例报道了使用锁定板的手术治疗枪支弹丸引起的下颌骨骨折。介绍了该系统的指示,优点和缺点。