Mechanical failure of angle locking plates in distal comminuted tibial fractures

机译:远端粉碎胫骨骨折角度锁定板的机械故障

获取原文

摘要

Distal comminuted tibial fracture with or without intra-articular involvement is a very common injury of the lower limb, especially in younger patients due to high energy trauma. The anatomical and biomechanical properties of this segment of tibia, makes this pathology a major surgical challenge with a preserved clinical outcome. The aim of this study is to present different outcome of tibial fracture, treated with open reduction and internal fixation (ORIF) with titanium angle locking plates (ALP) and to underline the physiological and non-physiological bone healing effects on implants. In this study we included 48 patients with tibial pilon fracture who underwent to ORIF, applying ALP in the Orthopedics and Trauma department of the University Emergency Hospital in Bucharest. Due to preserved biomechanical properties of ALP and this anatomical region, weight bearing is not allowed till 6 to 8 weeks. Comminuted fracture of this part of tibia often have de-vascularized bony fragments which leads to delayed union or non-union. These complications often lead to implant failure, improper bone healing or non-union. Internal fixation with angle stable screws, offers a good stability of reduction in the early postoperative period. Titanium angle locking plates offers good anatomical reduction and stable fixation in the early period of healing process. Due to its rigid, fixed position of the screws in the plates, bone remodelling during healing process and early weight bearing, increases the mechanical failure of implant.
机译:远端粉碎胫骨骨折有或没有关节内参与的是较低肢体的常见损伤,特别是在较年轻的患者上,由于高能量创伤。这种胫骨细胞的解剖学和生物力学特性,使这种病理具有保存的临床结果的主要手术挑战。本研究的目的是呈现不同的胫骨骨折结果,用钛角锁定板(ALP)进行开放减少和内固定(orif),并强调植入物的生理和非生理骨愈合作用。在这项研究中,我们包括48名患有48名患有胫骨皮骨骨折的患者,患有orif,在布加勒斯特大学急诊医院的骨科和创伤部门施用ALP。由于ALP的保存生物力学和该解剖区域,重量轴承不允许轴承直至6至8周。胫骨这一部分的粉碎骨折通常具有脱血管化的骨碎片,导致延迟联合或非联合。这些并发症往往导致植入失败,骨愈合不当或非union。与角度稳定螺钉的内部固定,在术后早期减少的稳定性稳定。钛角锁定板在愈合过程的早期内部提供良好的解剖学减少和稳定的固定。由于其刚性,螺钉的固定位置在板中,愈合过程中的骨质重塑和早重轴承,增加了植入物的机械故障。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号