Interaction of diagnostic ultrasound with gas bodies produces a useful contrast effect in medical images, but the same interaction also represents a mechanism for bioeffects. Anesthetized hairless mice were scanned by using a 2.5-MHz transducer (610-ns pulses with 3.6-kHz repetition frequency and 61-Hz frame rate) after injection of Optison and Evans blue dye. Petechial hemorrhages (PHs) in intestine and abdominal muscle were counted 15 min after exposure to characterize capillary rupture, and Evans blue extravasation was evaluated in samples of muscle tissue. For 5 ml⋅kg-1 contrast agent and exposure to 10 alternating 10-s on and off periods, PH counts in muscle were approximately proportional to the square of peak negative pressure amplitude and were statistically significant above 0.64 MPa. PH counts in intestine and Evans blue extravasation into muscle tissue were significant above 1.0 MPa. The PH effect in muscle was proportional to contrast dose and was statistically significant for the lowest dose of 0.05 ml⋅kg-1. The effects decreased nearly to sham levels if the exposure was delayed 5 min. The PH effect in abdominal muscle was significant and statistically indistinguishable for uninterrupted 100-s exposure, 10-s exposure, 100 scans repeated at 1 Hz, and even for a single scan. The results confirms a previous report of PH induction by diagnostic ultrasound with contrast agent in mammalian skeletal muscle [Skyba, D. M., Price, R. J., Linka, A. Z., Skalak, T. C. & Kaul, S. (1998) Circulation 98, 290–293].
机译:诊断超声与气体主体的相互作用在医学图像中产生有用的对比效果,但是相同的相互作用也代表了生物效应的机制。注射Optison和Evans蓝染料后,使用2.5 MHz传感器(610 ns脉冲,3.6 kHz重复频率和61 Hz帧频)扫描麻醉的无毛小鼠。暴露后15分钟对肠道和腹肌的小儿出血(PHs)进行计数,以表征毛细血管破裂,并在肌肉组织样本中评估伊文思蓝外渗。对于5ml⋅kg -1 造影剂,并在10次交替的开/关周期内暴露,肌肉中的PH值与负压峰值幅度的平方成正比,并且在0.64以上具有统计学意义MPa。高于1.0 MPa时,肠道中的PH值和伊文思蓝渗透到肌肉组织中均显着。肌肉中的PH值与对比剂量成正比,最低剂量为0.05 ml·kg -1 具有统计学意义。如果将接触延迟5分钟,则影响几乎降低至假手术水平。对于不间断的100秒曝光,10秒曝光,以1 Hz的频率重复100次扫描,甚至单次扫描,腹肌中的PH效果均显着且在统计上无法区分。结果证实了以前用超声造影剂在哺乳动物骨骼肌中用超声造影剂诱导PH的报道[Skyba,DM,Price,RJ,Linka,AZ,Skalak,TC&Kaul,S.(1998)Circulation 98,290-293] 。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号