首页> 美国卫生研究院文献>Molecules >Simultaneous Determination of 24 Antidepressant Drugs and Their Metabolites in Wastewater by Ultra-High Performance Liquid Chromatography–Tandem Mass Spectrometry
【2h】

Simultaneous Determination of 24 Antidepressant Drugs and Their Metabolites in Wastewater by Ultra-High Performance Liquid Chromatography–Tandem Mass Spectrometry

机译:高效液相色谱-串联质谱法同时测定废水中的24种抗抑郁药及其代谢物

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Antidepressants are a new kind of pollutants being increasingly found in wastewater. In this study, a fast and sensitive ultra-high performance liquid chromatography-tandem mass spectrometry method was developed and validated for the analysis of 24 antidepressant drugs and six of their metabolites in wastewater. This is the first time that the antidepressant residues in wastewater of Beijing (China) were systematically reported. A solid-phase extraction process was performed with 3 M cation disk, followed by ultra-high performance liquid chromatography–tandem mass spectrometry measurements. The chromatographic separation and mass parameters were optimized in order to achieve suitable retention time and good resolution for analytes. All compounds were satisfactorily determined in one single injection within 20 min. The limit of quantification (LOQ), linearity, and extraction recovery were validated. The LOQ for analytes were ranged from 0.02 to 0.51 ng/mL. The determination coefficients were more than 0.99 within the tested concentration range (0.1–25 ng/mL), and the recovery rate for each target compound was ranged from 81.2% to 118% at 1 ng/mL. This new developed method was successfully applied to analysis the samples collected from Beijing municipal wastewater treatment plants. At least ten target antidepressants were found in all samples and the highest mean concentration of desmethylvenlafaxin was up to 415.6 ng/L.
机译:抗抑郁药是在废水中越来越多地发现的一种新型污染物。在这项研究中,建立了一种快速灵敏的超高效液相色谱-串联质谱法,并已用于分析废水中的24种抗抑郁药及其6种代谢产物。这是首次系统报告北京(中国)废水中的抗抑郁药残留。用3 M阳离子盘进行固相萃取,然后进行超高效液相色谱-串联质谱测量。优化了色谱分离和质量参数,以实现合适的保留时间和对分析物的良好分离度。在20分钟内一次注射即可令人满意地测定所有化合物。验证了定量限(LOQ),线性和提取回收率。分析物的最低定量限为0.02至0.51 ng / mL。在测试浓度范围(0.1–25 ng / mL)中,测定系数大于0.99,每种目标化合物的回收率在1 ng / mL时为81.2%至118%。这种新开发的方法已成功地用于分析从北京市市政污水处理厂收集的样品。在所有样品中至少发现了十种目标抗抑郁药,去甲基文拉法辛的最高平均浓度高达415.6 ng / L。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号