Shape Analysis of the Patellar Bone Surface and Cutting Plane for Knee Replacement Surgery

机译:膝关节置换手术的the骨表面和切割平面的形状分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Geometry of the patella (kneecap) remains poorly understood yet is highly relevant to performing the correct patellar cut to reduce pain and to improve function and satisfaction after knee replacement surgery. Although studies routinely refer to “parallel to the anterior surface” and “the patellar horizon,” a quantitative definition of these is lacking and significant variability exists between observers for this irregularly-shaped bone. A 2D-3D shape analysis technique was developed to determine the optimal device configuration for contacting the patellar surface. Axial and sagittal pseudo-X-rays were created from 18 computed tomography (CT) scans of cadaveric knees. Four expert surgeons reviewed three repetitions of the X-rays in randomized order, marking their desired cut plane and their estimate of the anterior surface. These 2D results were related back to the 3D model to create the desired plane. There was considerable variability in perceptions, with intra- and intersurgeon repeatability (standard deviations) ranging from 1.3° to 2.4°. The best configuration of contact points to achieve the desired cutting plane was three pegs centred on the patellar surface, two superior and one inferior, forming a 16 mm equilateral triangle. This configuration achieved predicted cut planes within 1° of the surgeon ranges on all 18 patellae. Implementing this, as was done in a subsequent prototype surgical device, should help improve the success and satisfaction of knee replacement surgery.
机译:remains骨(膝盖骨)的几何形状仍知之甚少,但与进行正确的pa骨切割以减轻疼痛并改善膝关节置换术后的功能和满意度高度相关。尽管研究通常指的是“平行于前表面”和“ horizo​​n骨水平线”,但缺乏对它们的定量定义,并且观察者之间对于这种不规则形状的骨骼存在明显的变异性。开发了2D-3D形状分析技术,以确定与the骨表面接触的最佳装置配置。通过对尸体膝盖进行18次计算机断层扫描(CT)扫描,创建了轴向和矢状伪X射线。四个专业的外科医生以随机顺序检查了三个重复的X射线,标出了他们想要的切面和对前表面的估计。这些2D结果与3D模型相关,以创建所需的平面。知觉方面存在很大差异,术中和术中重复性(标准差)的范围为1.3°至2.4°。达到所需切割平面的最佳接触点配置是在three骨表面居中的三个栓钉,两个上方和一个下方,形成一个16 mm的等边三角形。这种配置在所有18根pat骨上均达到了距手术医生范围1°以内的预测切面。如在随后的原型手术设备中所做的那样,实施此操作应有助于提高膝关节置换手术的成功率和满意度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号