首页> 美国卫生研究院文献>Environmental Health Perspectives >Comparison of chemical-activated luciferase gene expression bioassay and gas chromatography for PCB determination in human serum and follicular fluid.
【2h】

Comparison of chemical-activated luciferase gene expression bioassay and gas chromatography for PCB determination in human serum and follicular fluid.

机译:化学活化荧光素酶基因表达生物测定和气相色谱法测定人血清和卵泡液中PCB的比较。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We assessed exposure to dioxin-like compounds using chemical and bioassay analysis in different matrices in a female population. A total of 106 serum and 9 follicular fluid samples were collected from infertile women attending Centers for Reproductive Medicine in Belgium from 1996 to 1998. Major polychlorinated biphenyl (PCB) congeners were quantified by chemical analysis using gas chromatography with electron-capture detection, and the chemical-activated luciferase gene expression (CALUX) bioassay was used to determine the total dioxin-like toxic equivalence (TEQ) of mixtures of polyhalogenated aromatic hydrocarbons present in body fluids, such as serum and follicular fluid. To the best of our knowledge, this is the first investigation to determine TEQ values by the CALUX bioassay in follicular fluid. The TEQ levels in both matrices are well correlated (r = 0.83, p = 0.02). As the chemical and bioassay analysis executed in this study do not cover the same span of polyhalogenated aromatic hydrocarbons, we did not expect totally correlated results. Moreover, the sample workup and quantification of the analytes differed completely. Nonetheless, the TEQ values in human extracts correlated well with the sum of four major PCB congeners chemically determined in both serum and follicular fluid. These results indicate that the CALUX bioassay may serve as a simple, relatively inexpensive prescreening tool for exposure assessment in epidemiologic surveys.
机译:我们使用化学和生物分析方法在女性人群的不同基质中评估了二恶英样化合物的暴露。从1996年至1998年,从比利时生殖医学中心的不育妇女中收集了106份血清和9份卵泡液样品。主要的多氯联苯(PCB)同源物通过气相色谱-电子捕获检测法进行化学分析,然后进行定量分析。化学激活的荧光素酶基因表达(CALUX)生物测定法用于测定体液(例如血清和卵泡液)中存在的多卤代芳香烃混合物的总二恶英样毒性当量(TEQ)。据我们所知,这是首次通过CALUX生物测定法在卵泡液中确定TEQ值的研究。两种基质中的TEQ含量均具有很好的相关性(r = 0.83,p = 0.02)。由于这项研究中进行的化学和生物测定分析没有涵盖相同范围的多卤代芳烃,因此我们没有期望得到完全相关的结果。而且,样品处理和分析物定量完全不同。尽管如此,人提取物中的TEQ值与血清和卵泡液中化学测定的四种主要PCB同类物质的总和相关性很好。这些结果表明,CALUX生物测定可以作为一种简单,相对便宜的预筛查工具,用于流行病学调查中的暴露评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号