Typical but uncommon computed tomography angiographic appearance of left ventricular assist device: Awareness is key!

机译:左心室辅助装置的典型但不常见的计算机断层扫描血管造影外观:认识是关键!

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Left ventricular assist devices (LVAD) are now a standard of care for patients awaiting heart transplant. Our patient had undergone placement of the HeartWare LVAD and presented to the hospital with complaints of fatigue, dyspnea, fever and discharge from the LVAD site. She underwent computed tomography angiography (CTA) to evaluate the LVAD. CTA revealed a hypodense area surrounding the outflow graft throughout its extent. This was suspicious of a thrombus. The repeat CTA performed 4 days later did not show any change in appearance of the outflow graft. This appearance was in fact due to the co-axial relationship of the two outflow grafts creating a potential space between them that can be filled with blood. This is a normal appearance and should not be mistaken for a thrombus. The awareness of the normal imaging appearance of the LVAD devices is essential to avoid unnecessary surgical intervention.
机译:左心室辅助设备(LVAD)现在已成为等待心脏移植的患者的标准治疗方法。我们的患者接受了HeartWare LVAD的放置,并因疲劳,呼吸困难,发烧和LVAD部位出院而被送往医院。她接受了计算机断层扫描血管造影(CTA)评估LVAD。 CTA揭示了在整个范围内围绕流出移植物的低密度区域。这对血栓有所怀疑。 4天后进行的重复CTA未显示流出移植物的外观有任何变化。实际上,这种外观是由于两个流出移植物的同轴关系,在它们之间形成了一个可能充满血液的潜在空间。这是正常现象,不应误认为是血栓。 LVAD设备正常成像外观的认识对于避免不必要的手术干预至关重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号