首页> 美国卫生研究院文献>Foods >Macular Pigment Optical Density and Measures of Macular Function: Test-Retest Variability Cross-Sectional Correlations and Findings from the Zeaxanthin Pilot Study of Response to Supplementation (ZEASTRESS-Pilot)
【2h】

Macular Pigment Optical Density and Measures of Macular Function: Test-Retest Variability Cross-Sectional Correlations and Findings from the Zeaxanthin Pilot Study of Response to Supplementation (ZEASTRESS-Pilot)

机译:黄斑色素的光密度和黄斑功能的措施:重测变异性截面相关性和玉米黄质对补充反应的初步研究的发现(ZEASTRESS-Pilot)

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We report on the short-term test-retest baseline variability in macular function tests in ZEASTRESS-Pilot participants (n = 18), on their cross-sectional correlation with macular pigment optical density (MPOD), and on the effects of four months (FUV4) of 20 mg/day zeaxanthin (ZX), followed by a four-month washout (FUV8; n = 24, age 50–81 years old). Outcomes included: MPOD at 0.5 and 2.0 deg eccentricity (MPOD-0.5 and -2.0); contrast sensitivity (CS); pattern-reversal electroretinogram (PERG) amplitude; dark-adapted 650 nm foveal cone sensitivity (DA650-FCS); and 500 mn parafoveal rod sensitivity (DA500-PFRS). All measures of macular function showed close test-retest correlation (Pearson’s r range: 0.744–0.946) and low coefficients of variation (CV range: 1.13%–4.00%). MPOD correlated in a complex fashion with macular function. Following supplementation, MPOD-0.5 and MPOD-2.0 increased at both FUV4 and FUV8 (p ≤ 0.0001 for all measures). Continued, delayed MPOD increase and a small, but significant (p = 0.012), CS increase was seen at FUV8 only in females. PERGs increased significantly at FUV4 (p = 0.0006), followed by a partial decline at FUV8. In conclusion, following ZX supplementation, MPOD increased significantly. There was no effect on DA-650 FCS or DA-500 PFRS. Both CS and PERG amplitudes increased following supplementation, but the effect varied between males and females. Additional studies appear warranted to confirm and characterize further these inter-gender differences.
机译:我们报告了ZEASTRESS-Pilot参与者(n = 18)在黄斑功能测试中的短期再测基线变异性,与黄斑色素光密度(MPOD)的横截面相关性以及四个月的影响( FUV4)每天20毫克玉米黄质(ZX),然后进行四个月的冲洗(FUV8; n = 24,年龄50-81岁)。结果包括:MPOD偏心度为0.5和2.0度(MPOD-0.5和-2.0);对比敏感度(CS);模式反转视网膜电图(PERG)幅度;暗适应性650 nm中央凹圆锥敏感度(DA650-FCS);以及5亿颗黄斑中心凹杆敏感性(DA500-PFRS)。黄斑功能的所有指标均显示出紧密的重测相关性(皮尔逊氏r范围:0.744–0.946)和低变异系数(CV范围:1.13%–4.00%)。 MPOD以复杂的方式与黄斑功能相关。补充后,FUV4和FUV8的MPOD-0.5和MPOD-2.0均增加(所有措施的p≤0.0001)。持续的MPOD延迟增加,以及仅在女性中在FUV8处观察到CS的增加,但幅度很小(p = 0.012)。 PERGs在FUV4处显着增加(p = 0.0006),然后在FUV8处部分下降。总之,补充ZX后,MPOD显着增加。对DA-650 FCS或DA-500 PFRS没有影响。补充后CS和PERG振幅均增加,但男性和女性之间的影响有所不同。似乎有必要进行其他研究,以确认并进一步表征这些性别间差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号