摘要

>Background: This study aimed at analyzing microbial contamination in medical equipment, environment, and staff of a gastroenterology unit. >Methods: Samples of gastrointestinal imaging devices, the environment, and staff were collected using standard swab-rinse technique and biochemical or molecular characteristics of the isolates, their susceptibility to antibiotics, and similarity of the resistance patterns were investigated. >Results: Out of 107 samples, bacterial contamination was detected in the hands of staff (54.1%), imaging devices (56.7%), and in the environment (54.5%). While Pseudomonas spp. were detected only in the imaging devices (13.5%), Bacillus spp. (32.4% and 31.5%), Enterococcus spp. (14.3% and 5.9%), Clostridium difficile (10.8% and 10.5%), and Staphylococcus epidermidis (5.4% and 15.9%) were orderly the most common isolates from samples of the imaging devices and the environment. Nearly, 40% of P. aeruginosa strains were resistant to cefepime, while resistance to cephalosporins and β-lactamase inhibitor was detected in 33% and 75% of S. aureus strains, respectively. Homology of resistance patterns was detected between the imaging devices and hands of the staff. >Conclusion: Our results proposed biofilm and spore forming bacteria as main contaminants of imaging devices in this hospital. Homology of the resistance patterns proposed involvement of staff in contamination of the equipment.
机译:>背景:本研究旨在分析医疗设备,环境和胃肠病科人员中的微生物污染。 >方法:使用标准拭子冲洗技术收集胃肠道成像设备,环境和工作人员的样本,并分离菌株的生化或分子特征,对抗生素的敏感性以及耐药模式的相似性。 >结果:在107个样本中,在工作人员手中(54.1%),成像设备(56.7%)和环境(54.5%)中检测到细菌污染。而假单胞菌属。仅在成像设备(13.5%)芽孢杆菌属中检测到。 (32.4%和31.5%),肠球菌。 (14.3%和5.9%),艰难梭菌(10.8%和10.5%)和表皮葡萄球菌(5.4%和15.9%)是从成像设备和环境样品中最常见的分离株。几乎有40%的铜绿假单胞菌菌株对头孢吡肟耐药,而分别在33%和75%的金黄色葡萄球菌菌株中检​​出对头孢菌素和β-内酰胺酶抑制剂的耐药性。在成像设备和工作人员的手之间检测到电阻模式的同源性。 >结论:我们的结果提出生物膜和形成孢子的细菌是该医院成像设备的主要污染物。抵抗模式的同源性建议工作人员参与设备的污染。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号