Hazardous Drug Contamination of Drug Preparation Devices and Staff: A Contamination Study Simulating the Use of Chemotherapy Drugs in a Clinical Setting

机译:药物制备装置和工作人员的有害药物污染:一项在临床环境中模拟化学疗法药物使用的污染研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: Hazardous drug contamination (HD) in healthcare environments continues, placing healthcare staff at risk of significantly chronic health problems, despite the use of personal protective equipment (PPE) and closed system transfer device systems (CSTDs). >Objective: This study’s aim was to determine how HD might spread through touch after handling contaminated vials in simulated pharmacy and nursing environments. >Methods: UV fluorescent powder Glo Germ (Glo Germ Co., Moab, UT), composed of melamine resin, was used to simulate HD. Following manufacturer’s exact usage specifications, five commercially available CSTDs were tested in the simulated pharmaceutical preparation environment under controlled conditions. UV fluorescence was used to detect the test medium powder that simulated HD following each trial. Photographs, using a Nikon D40X (10.2 mp) camera, were taken at selected stages of testing to document the presence of HD. >Results: Transfer of the HD testing medium (Glo Germ) to IV sets, pharmacy PPE, and nursing PPE was observed in 4 of 5 CSTDs tested. The only CSTDs that showed no observable contamination was the Allison Medical Safety Enclosed Vial Adapter (SEVA) system (Littleton, CO). >Conclusions: Results show residue from HD vials spread as vial was handled in a pharmacy environment in 4 of 5 CSTDs, contaminating pharmacy PPE, ancillary products, and nursing PPE. No HD residue was detected on PPE, ancillary products, or nursing PPE in the pharmacy after using the SEVA system, providing an effective means to contain HD for drug transfer from vial to delivery system.
机译:>背景:尽管使用了个人防护设备(PPE)和封闭系统传输设备系统(CSTD),医疗环境中的危险药物污染(HD)仍在继续,使医护人员面临严重的慢性健康问题的风险。 。 >目的:本研究的目的是确定在模拟的药房和护理环境中处理受污染的药瓶后HD如何通过触摸传播。 >方法:使用由三聚氰胺树脂组成的UV荧光粉Glo Germ(Glo Germ Co.,莫阿布,犹他州)来模拟高清。按照制造商的确切用法规格,在受控条件下在模拟药物制备环境中测试了五种市售CSTD。每次试验后,使用UV荧光检测模拟HD的测试培养基粉末。在选定的测试阶段,使用尼康D40X(10.2 mp)相机拍摄了照片,以记录高清的存在。 >结果:在5个CSTD中,有4个将HD测试介质(Glo Germ)转移到了静脉输液器,药房PPE和护理PPE。唯一未显示可观察到污染的CSTD是Allison医疗安全封闭式瓶装适配器(SEVA)系统(科罗拉多州利特尔顿)。 >结论:结果显示,HD药瓶中的残留物是在药房中5个CSTD中的4个在药房环境中处理的,污染了药房PPE,辅助产品和护理PPE。使用SEVA系统后,在药房中的PPE,辅助产品或护理PPE上未检测到HD残留,从而提供了一种有效的方法来包含HD以将药物从小瓶转移到输送系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号