首页> 美国卫生研究院文献>Gut >Does bipolar electrocoagulation time affect vessel weld strength?
【2h】

Does bipolar electrocoagulation time affect vessel weld strength?

机译:双极电凝时间会影响血管的焊接强度吗?

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The value of the bipolar electrocoagulator in the haemostasis of bleeding ulcers is controversial. We have therefore investigated the effect of different coagulation times on vessel weld strength achieved by the bipolar device. Welds were then made in vessels of known diameter using a standard 10F endoscopic haemostatic probe at coagulation times of two and 20 seconds. The intravascular temperature achieved at each time was measured. Vessel weld strength achieved by bipolar electrocoagulation was much greater at 20 seconds (approximately twice that at two seconds) and was highly significantly greater at all vessel diameters. There was a gradual reduction in weld strength with increasing vessel diameter, an effect that was seen for both two and 20 seconds of electrocoagulation. Intravascular temperature was significantly higher at 20 seconds than at two seconds. We conclude that vessel weld strength is related to coagulation time and that any future studies comparing the bipolar electrocoagulator with other haemostatic devices should use longer periods of bipolar electrocoagulation and record the coagulation time in order to optimise the clinical value of the device.
机译:双极电凝器在止血溃疡止血中的价值是有争议的。因此,我们研究了不同凝结时间对双极型设备实现的容器焊接强度的影响。然后使用标准的10F内窥镜止血探针在2到20秒的凝固时间下在已知直径的容器中进行焊接。测量每次达到的血管内温度。通过双极电凝获得的容器焊接强度在20秒时要高得多(大约是2秒时的两倍),并且在所有容器直径下都显着更高。随着容器直径的增加,焊接强度逐渐降低,这种现象在电凝的2秒和20秒中都可以看到。 20秒时的血管内温度明显高于2秒时。我们得出的结论是,血管焊接强度与凝固时间有关,将来任何将双极电凝器与其他止血装置进行比较的研究都应使用更长的双极电凝时间并记录凝固时间,以优化装置的临床价值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号