首页> 美国卫生研究院文献>International Journal of Dentistry >Rapid Quantification of Bacteria in Infected Root Canals Using Fluorescence Reagents and a Membrane Filter: A Pilot Study on Its Clinical Application to the Evaluation of the Outcomes of Endodontic Treatment
【2h】

Rapid Quantification of Bacteria in Infected Root Canals Using Fluorescence Reagents and a Membrane Filter: A Pilot Study on Its Clinical Application to the Evaluation of the Outcomes of Endodontic Treatment

机译:使用荧光试剂和膜滤器快速定量感染根管中的细菌:其临床应用在评估牙髓治疗结果中的初步研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective. The bacterial examination has been performed during the course of the root canal treatment. In the present pilot study, the new developed method, using fluorescence reagents and a membrane filter, was applied to the detection and quantification of bacteria in infected root canals, in order to evaluate the outcomes of the treatment. Methods. Six infected root canals with periapical lesions from 5 subjects were included. Informed consent was obtained from all subjects (age ranges, 23–79 years). Samples from infected root canals were collected at the beginning of the treatment (termed #25 First), the end of the first day of treatment (termed #55 First), and the next appointment day (termed #55 Second). Then, the bacterial count (CFU) was measured using fluorescence reagents (4′,6′-diamidino-2-phenylindole and propidium iodide) and the polycarbonate membrane filter by Bioplorer. Results. The mean ± SD of CFU in the sample of “#25 First” was (1.0 ± 1.4) × 105. As the root canal treatment progressed, the CFU decreased as 7.9 × 103 (#55 First) and 4.3 × 102 (#55 Second). Conclusion. In the present pilot study, rapid detection and quantification of bacteria in infected root canals were found to be successfully performed using fluorescence reagents and a membrane filter (Bioplorer analysis).
机译:目的。在根管治疗过程中进行了细菌检查。在当前的初步研究中,使用荧光试剂和膜滤器的新开发方法被用于检测和定量感染根管中的细菌,以评估治疗效果。方法。包括来自5位受试者的6条感染的根尖周损伤的根管。所有受试者均获得知情同意(年龄范围23-79岁)。在治疗开始时(称为#25 First),治疗第一天结束(称为#55 First)和下一个约会日(称为#55 Second),从感染的根管中收集样品。然后,使用荧光试剂(4',6'-二mid基-2-苯基吲哚和碘化丙啶)和Bioplorer的聚碳酸酯膜过滤器测量细菌计数(CFU)。结果。 “#25 First”样品中CFU的平均值±SD为(1.0±1.4)×10 5 。随着根管治疗的进展,CFU分别下降为7.9×10 3 (第55名)和4.3×10 2 (第55名)。结论。在当前的初步研究中,发现使用荧光试剂和膜过滤器(Bioplorer分析)可以成功地快速检测和定量感染根管内的细菌。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号