High-throughput liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) methodology for the determination of methamphetamine (METH), amphetamine (AMP), 4-hydroxymethamphetamine (4-OH-METH), and 4-hydroxyamphetamine (4-OH-AMP) was developed and validated using simple trichloroacetic acid sample treatment. The method was validated in rat serum, brain, and testis. Lower limits-of-quantitation (LOQ) for METH and AMP were 1 ng·mL−1 using positive ion electrospray tandem mass spectrometry (MS/MS). The accuracy of the method was within 25% of the actual values over a wide range of analyte concentrations. The within-assay precision was better than 12% (coefficient of variation). The method was linear over a wide dynamic range (0.3–1000 ng·mL−1). Quantitation was possible in all 3 matrices using only serum standards because of minimal matrix-associated ion effects or the use of an internal standard. Finally, the LC-MS/MS method was used to determine serum, brain, and testis METH and AMP concentrations during a subcutaneous infusion (5.6 mg kg−1 day−1) of METH in rats. Concentrations of 4-OH-AMP and 4-OH-METH were below the LOQ in experimental samples. The bias introduced by using serum calibrators for the determination of METH and AMP concentrations in testis and brain was less than 8% and insignificant relative to the interanimal variability.
机译:高通量液相色谱-串联质谱检测(LC-MS / MS)方法用于测定甲基苯丙胺(METH),苯丙胺(AMP),4-羟基甲基苯丙胺(4-OH-METH)和4-羟基苯丙胺(4-使用简单的三氯乙酸样品处理技术开发并验证了OH-AMP)。该方法已在大鼠血清,脑和睾丸中得到验证。使用正离子电喷雾串联质谱法(MS / MS)对METH和AMP的定量下限(LOQ)为1 ng·mL -1 。在广泛的分析物浓度范围内,该方法的准确性在实际值的25%以内。批内精确度优于12%(变异系数)。该方法在较宽的动态范围(0.3–1000 ng·mL -1 )中呈线性。由于基质相关离子的影响最小或使用内标物,仅使用血清标准品就可以在所有3种基质中进行定量。最后,采用LC-MS / MS方法测定皮下输注(5.6 mg kg -1 day -1 )时的血清,脑和睾丸的METH和AMP浓度。 )在大鼠中。实验样品中4-OH-AMP和4-OH-METH的浓度低于LOQ。使用血清校准物测定睾丸和大脑中的METH和AMP浓度所产生的偏差小于8%,相对于动物间的变异性而言是微不足道的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号