首页> 美国卫生研究院文献>other >Simultaneous quantitative determination of bupropion and its three major metabolites in human umbilical cord plasma and placental tissue using high-performance liquid chromatography-tandem mass spectrometry
【2h】

Simultaneous quantitative determination of bupropion and its three major metabolites in human umbilical cord plasma and placental tissue using high-performance liquid chromatography-tandem mass spectrometry

机译:使用高效液相色谱 - 串联质谱法同时定量测定人脐胸等血浆和胎盘组织中的三大代谢物

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A liquid chromatography in tandem with electro-spray ionization mass spectrometry method has been developed and validated for the quantitative determination of BUP and its major metabolites (hydroxybupropion, threo- and erythrohydrobupropion) in human umbilical cord plasma and placental tissue. The samples were acidified with trichloroacetic acid, and protein precipitated by adding acetonitrile. Chromatographic separation of drug and metabolites was achieved by using a Waters Symmetry C18 column, with an isocratic elution of 31% methanol and 69% formic acid (0.04%, v/v) aqueous solution at a flow rate of 1.0 mL/min. Detection was carried out by mass spectrometry using positive electro-spray ionization mode, and the compounds were monitored using multiple reactions monitoring method. Deuterium-labeled isotopes of the compounds were used as internal standards. Calibration curves were linear (r2 >0.99) in the tested ranges. The lower limit of quantification of analytes in umbilical cord plasma samples is < 0.72 ng/mL and 0.92 ng/g in placental tissue samples. The relative deviation of this method was < 15% for intra- and inter-day assays, and the accuracy ranged between 88 and 105%. The extraction recovery of the four analytes ranged between 89 and 96% in umbilical cord plasma, and 64 and 80% in placental tissue. No significant matrix effect was observed in the presented method.
机译:已经开发并验证了具有电喷涂电离质谱法的串联酸液相制,并验证了人脐带等离子体和胎盘组织中的Bup及其主要代谢物(羟基丙酮,羟基丙杂物)的定量测​​定。用三氯乙酸酸化样品,并通过加入乙腈沉淀蛋白质。通过使用水对称C18柱实现药物和代谢物的色谱分离,以1.0ml / min的流速,具有31%甲醇和69%甲酸(0.04%,V / v)水溶液的等物质洗脱。使用正电喷雾电离模式通过质谱法进行检测,使用多重反应监测方法监测化合物。将化合物的氘标记的同位素用作内标。校准曲线在测试的范围内是线性的(R 2 0.99)。脐带等离子体样品中分析物中分析物的定量下限为<0.72ng / ml和0.92ng / g在胎盘组织样品中。该方法的相对偏差<15%的内部测定,精度范围为88至105%。四种分析物的提取恢复在脐带等离子体中的89至96%之间,胎盘组织中的64和80%。在呈现的方法中没有观察到显着的基质效应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号