A new class of micropumps based on electroosmotic flow has been developed. These micropumps are fabricated through silicon micromachining and incorporate electroosmotic flow elements consisting of parallel arrays of hundreds of narrow, deep trenches designed to enhance the transfer of momentum into the fluid phase. A comprehensive model of silicon electroosmotic micropump operation has been developed by adapting and extending the Burgreen-Nakache model of electroosmotic flow in slit capillaries. The newly developed model takes into account deviations from the ideal slit capillary geometry arising from silicon etch and thin film processes, as well as factors such as pressure losses and potential gradients within the micropump but external to the electroosmotic flow element.; Over sixty prototype silicon electroosmotic micropumps have been fabricated and tested. Prototype silicon electroosmotic micropumps with 1.5 cm 3 package sizes generate flow rates up to 170 muL min-1 and pressures of nearly 10 kPa. Using the newly developed micropump model to compare data for micropumps with different electroosmotic flow element geometries and for a range of operating voltages, micropump flow rate is seen to scale in proportion to the magnitude of the electric field in the electroosmotic flow element, while pressure scales in proportion to the total voltage drop across the electroosmotic flow element---findings consistent with established models of electroosmotic flow and electric double layers. The effect on micropump performance of dielectric thin film composition has been characterized, with zeta potentials found to be approximately -20 mV for nitride films and -40 mV for oxide-on-nitride films.; Critical processing steps in the silicon electroosmotic micropump fabrication process have been characterized in detail. Dielectric thin film deposition processes have been developed which mitigate substrate current sufficiently to permit micropump operation at up to 500 V. Trap-controlled hole conduction in the silicon nitride layer is proposed as the current-limiting mechanism in these films. Transient pressure response data has been obtained by laser vibrometry measurement of the deflection of integrated pressure-sensing diaphragms. Silicon electroosmotic micropumps have been evaluated for applications in integrated circuit thermal management and biological fluids analysis.
机译:已经开发出基于电渗流的新型微型泵。这些微型泵是通过硅微机械加工制造的,并包含电渗流元件,该元件由数百个窄而深的沟槽的平行阵列组成,旨在增强动量向液相的传递。通过适应和扩展狭缝毛细管中电渗流的Burgreen-Nakache模型,开发了硅电渗流微泵操作的综合模型。新开发的模型考虑了由于硅蚀刻和薄膜工艺而产生的与理想狭缝毛细管几何形状的偏差,以及诸如微泵内部但在电渗流元件外部的压力损失和电势梯度等因素。已经制造和测试了六十多个原型硅电渗微泵。封装尺寸为1.5 cm 3的原型硅电渗透微泵产生的流速高达170μLmin-1,压力接近10 kPa。使用新开发的微型泵模型比较具有不同电渗流元件几何形状和一系列工作电压的微型泵的数据,可以看到微型泵的流量与电渗流元件中电场的大小成比例,而压力成比例与电渗流元件上的总压降成正比-发现与建立的电渗流和双电层模型一致。已经表征了对介电薄膜组合物的微泵性能的影响,发现氮化物膜的ζ电势约为-20mV,氮氧化物膜的ζ电势约为-40mV。硅电渗透微泵制造工艺中的关键加工步骤已得到详细描述。已经开发出了介电薄膜沉积工艺,该工艺可以充分缓解衬底电流以允许微泵在高达500 V的电压下工作。氮化硅层中陷阱控制的空穴传导被提议作为这些膜中的限流机制。瞬态压力响应数据已通过激光振动测定法测量了集成压力传感膜片的挠度。硅电渗透微型泵已经过评估,可用于集成电路热管理和生物流体分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号