The Qinling Long Sized Road Tunnel (Qinling Tunnel) is the longest road tunnel in China. Torninvestigate the behaviours of fire and to propose an effective ventilation measure to fight fires in thernQinling Tunnel, two large-scaled model tunnel was established and a series of fire testing werernconducted. The scopes of the testing are: (1) general behaviours of fire; (2) applicable fire ventilationrnmeasures when fire occurs at the various positions of the tunnel. The results show: (1) the temperature,rnpressure and smoke flow vary significantly with air velocity and fire load; (2) According to the firernload applied and ventilation condition, the temperature reached the maximum value within 2-10 minrnafter ignition; 3) the forced ventilation has both positive and negative effects on fires; (4) when firernbreaks out in the Qinling Tunnel, the effective ventilation measure should be applied according to firernposition, fire load and evacuation procedures.
机译:秦岭长距离公路隧道(秦岭隧道)是中国最长的公路隧道。对秦岭隧道的火灾行为进行调查研究,提出有效的通风措施,扑灭秦岭隧道,建立了两条大型模型隧道,并进行了一系列的火灾测试。试验范围是:(1)火灾的一般行为; (2)隧道各部位发生火灾时的适用消防通风措施。结果表明:(1)温度,压力,烟气流量随风速和火力的变化而变化较大; (2)根据所施加的负荷和通风条件,在点火后2-10分钟内温度达到最大值; 3)强制通风对火有正面和负面影响; (4)在秦岭隧道内发生大火时,应根据大火的位置,火负荷及疏散程序采取有效的通风措施。