首页> 美国卫生研究院文献>other >Numerical modeling of water spray suppression of conveyor belt fires in a large-scale tunnel
【2h】

Numerical modeling of water spray suppression of conveyor belt fires in a large-scale tunnel

机译:大型隧道输送带火灾喷水抑制的数值模拟

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Conveyor belt fires in an underground mine pose a serious life threat to miners. Water sprinkler systems are usually used to extinguish underground conveyor belt fires, but because of the complex interaction between conveyor belt fires and mine ventilation airflow, more effective engineering designs are needed for the installation of water sprinkler systems. A computational fluid dynamics (CFD) model was developed to simulate the interaction between the ventilation airflow, the belt flame spread, and the water spray system in a mine entry. The CFD model was calibrated using test results from a large-scale conveyor belt fire suppression experiment. Simulations were conducted using the calibrated CFD model to investigate the effects of sprinkler location, water flow rate, and sprinkler activation temperature on the suppression of conveyor belt fires. The sprinkler location and the activation temperature were found to have a major effect on the suppression of the belt fire, while the water flow rate had a minor effect.
机译:地下矿井中的传送带火灾对矿工构成了严重的生命威胁。通常使用喷水灭火系统来扑灭地下传送带火灾,但是由于传送带火灾和矿井通风气流之间的复杂相互作用,因此需要更有效的工程设计来安装喷水灭火系统。建立了计算流体动力学(CFD)模型,以模拟矿井入口通风气流,皮带火焰传播和喷水系统之间的相互作用。 CFD模型是使用大型传送带灭火实验的测试结果进行校准的。使用校准的CFD模型进行了模拟,以研究喷头位置,水流量和喷头激活温度对抑制传送带火灾的影响。发现喷淋头的位置和活化温度对抑制带火起主要作用,而水流量影响不大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信